EasyManua.ls Logo

Automationdirect.com DURApulse GS10 - GS10 AC Drive Terminal Configurations; Two-Wire Operation Control Settings; Three-Wire Operation Control Setting; GS10 AC Drive Wiring Terminal Specifications

Automationdirect.com DURApulse GS10
5 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 2GS10 AC Drive Quick-Start Guide – 1st Ed 06/15/2022
DURApulse GS10 AC Drive Quick-Start Guide
GS10_QSP 1st Edition 06/15/2022
P02.00 External Terminal Control Circuits
Setting value: 1
Two-wire operation control
FWD / STOP
REV / STOP
FWD/DI1
REV/DI2
DCM
GS10
REV
RUN
FWD
RUN
STOP
Setting value: 2
Two-wire operation control
RUN / STOP
FWD / REV
FWD/DI1
REV/DI2
DCM
GS10
Setting value: 3
Three-wire operation control
FWD/DI1
REV/DI2
DCM
GS10
DI3
Specifications for Wiring Terminals – Control Circuit
GS10-xxxx All Models; All Frame Sizes
Terminal Wire Gauge Torque
Control
24–18 AWG
[0.21–0.82 mm
2
]
n/a (spring terminals)
Relay
24–16 AWG
[0.21–1.31 mm
2
]
5kg·cm
[4.3 lb·in]
Control Terminal Distribution Diagram Control Terminal Location Map
FWD
REV
DI3
DI4
DI5
AI
AO1
DO1
DOC
R1O
R1C
R1
Wiring Precautions
1) The RELAY terminal uses the PCB terminal block:
Tighten the wiring with a 3.5 mm width and 0.6 mm thickness slotted screwdriver.
The ideal length of stripped wire at the connection side is 9–10 mm.
When wiring bare wires, make sure they are perfectly arranged to go through the wiring holes.
2) The control circuit terminal uses a spring clamp terminal block:
Tighten the wiring with a 2.5 mm width and 0.4 mm thickness slotted screwdriver.
The ideal length of stripped wire at the connection side is 9 mm.
Recommended models or dimensions for ferrule terminals
Wire Gauge Manufacturer Model Name A (MAX) B (MAX) D (MAX) W (MAX)
0.25 mm2
[24 AWG]
PHOENIX
CONTACT
AI 0,25- 8 YE 12.5 8 2.6 1.1
0.34 mm2
[22 AWG]
PHOENIX
CONTACT
AI 0,34- 8 TQ 12.5 8 3.3 1.3
0.5 mm2
[20 AWG]
PHOENIX
CONTACT
AI 0,5 - 8 WH 14 8 3.5 1.4
Specifications for Wiring Terminals – Main-Circuit Terminals
Notes:
If installation environment temperature is greater than 45°C, please use copper wire with a 600V voltage
rating and temperature resistance of 90°C or higher.
For UL compliant installation, you must:
1) Use 75°C temperature resistant copper wire or better. Do not reduce wire gauge when using higher
temperature wire.
2) Use the specific ring lug part listed in the table below.
3) Use crimp tool CRIMPFOX 10S - 1212045 (Phoenix Contact) or DNT13-0101 (Dinkle).
Drive Models
Max Wire
Gauge
Min Wire
Gauge
Screw
Torque
(±10%)
Ring Lug Dimensions (mm)
Frame Ax
GS11N-10P2
14AWG
[2.5 mm
2
]
14AWG
[2.5 mm
2
]
M3.5
9 kg-cm
[7.8 lb-in.]
[0.88 N·m]
Dimension Value Min/Max
A 9.8 Max
B 3.2 Max
C 4.8 Min
D 4.1 Max
d2 3.7 Min
E 13.0 Min
F 4.2 Min
W 6.6 Max
t 0.8 Max
GS11N-10P5
GS11N-20P2
GS11N-20P5
16AWG
[1.5 mm
2
]
GS13N-20P2
18AWG
[0.75 mm
2
]
GS13N-20P5
GS13N-21P0
16AWG
[1.5 mm
2
]
GS13N-40P5
18AWG
[0.75 mm
2
]
GS13N-41P0
Frame Bx
GS11N-21P0
12AWG
[4 mm
2
]
12AWG
[4 mm
2
]
M4
15 kg-cm
[13.0 lb-in.]
[1.47 N·m]
Dimension Value Min/Max
A 12.1 Max
B 3.6 Max
C 6.1 Min
D 5.6 Max
d2 4.3 Min
E 13.0 Min
F 4.5 Min
W 7.2 Max
t 1 Max
GS13N-22P0
GS13N-42P0
14AWG
[2.5 mm
2
]
Specifications for Wiring Terminals – Main-Circuit Terminals (continued)
Drive Models
Max Wire
Gauge
Min Wire
Gauge
Screw
Torque
(±10%)
Ring Lug Dimensions (mm)
Frame C
GS11N-11P0
8AWG
[10 mm
2
]
8AWG
[10 mm
2
]
M4
20 kg-cm
[17.4 lb-in.]
[1.96 N·m]
Dimension Value Min/Max
A 17.8 Max
B 5.0 Max
C 6.1 Min
D 7.2 Max
d2 4.3 Min
E 13.0 Min
F 5.5 Min
W 10.5 Max
t 1.2 Max
GS11N-22P0
GS11N-23P0
GS13N-23P0
10AWG
[6 mm
2
]
GS13N-25P0
8AWG
[10 mm
2
]
GS13N-43P0
14AWG
[2.5 mm
2
]
GS13N-45P0
12AWG
[4 mm
2
]
Frame D
GS13N-27P5
8AWG
[10 mm
2
]
8AWG
[10 mm
2
]
M4
20 kg-cm
[17.4 lb-in.]
[1.96 N·m]
Dimension Value Min/Max
A 17.8 Max
B 5.0 Max
C 6.1 Min
D 7.2 Max
d2 4.3 Min
E 13.0 Min
F 5.5 Min
W 10.5 Max
t 1.2 Max
GS13N-47P5
10AWG
[6 mm
2
]
GS13N-4010
8AWG
[10 mm
2
]