5
Operation Modes .
designed to heat an interior space as quickly as possible;
has 8 steps of the operation mode
;
the heater is constantly working at the set heat level..
designed to heat an interior space to a preset temperature;
decreases heating output when the difference between the
preset and actual temperatures is reduced.
designed to maintain a preset temperature in a space;
stops heating of the space after reaching the preset
temperature, then begins air ventilation;
controls the space temperature; when the temperature is
lowered below the preset level, the heater starts running in
heating mode.
Features of Operation Modes .
Ventilation mode is compatible with the Temperature Control and incompatible with the
Heat Control mode. In Heat Control mode the heater will not stop its heating operation
regardless of the middle LED display.
After each shutdown of the heater the activation of the Ventilation mode is reset.
When the Heat Control mode is selected, the heater constantly operates at the preset
level of heating power. When a comfortable temperature is reached, we recommend to
reduce the heat level or to ventilate the room.
When the Temperature Control mode is selected, the heater constantly operates to
maintain the preset temperature, while its heating power is changed ranging from max.
to min., depending on the ambient temperature. The higher the temperature, the less
heat the heater generates.
Changing the parameters of the heater (sensor selection, activation-deactivation of the
ventilation mode) is only possible before starting the heater, and it is impossible during
its operation