9
To unlock the heater you need to contact the service center.
Flameout in the
combustion
chamber due to
undervoltage
Check for the battery and wiring. (Undervoltage may occur
due to a prolonged use of the electric starter).
Detected
flameout during
operation.
Shown for user's information.
Check for the tightening of clamps on the fuel line, fuel line
leaks, and tightness of the fitting on the fuel pump.
** Attention! If, during the start-up and operation of the heater the error message
"Overheating" is repeated 3 times in a row, the heater will be locked. Locking is made upon
actual overheating, regardless of the input from the sensors that produced errors. In case of
locking, the controller display will show code 33. To unlock the heater you need to contact
a service center.
Alarm System Remote .
The operation of the heater can be controlled by a remote control of a security alarm
system, provided that it has a free channel.
Heater control can be carried out in two ways: with short-time closures of relay contacts
(closure time of 0.5 to 3 seconds) and with a long-time closure (longer than 3 seconds). With
short closures, the first pulse switches the heater ON, the second OFF. A prolonged closure
of relay contacts forms a Start-up command from the Remote, while the opening of contacts
sends a Shutdown command.
After starting, the heater will operate at "max" in the Heat Control mode. The time of
heater's operation – 2 hours. The operation of the heater can be interrupted from the alarm's
Remote or from the Controller.
The type of the Remote and the relay does not matter, as long as the relay consumption
current does not exceed the load capacity of the Remote's channel.
If the heater was started with the Controller, then, during its operation, the Start-up
command from the alarm Remote is ignored and operation parameters cannot be changed
* - only for the air heaters AIR-8D