R32 Split - Air to Water Heat Pump 20220105
7
Part2 Features
1. Heating + Cooling +Demostic hot water
2. DC Inverter Technology, High Energy Efficient
The compressor speed is controlled according to the indoor heating demand, and the output is completely on
demand, more comfortable enjoyment: In any case, it can maintain a stable indoor temperature
Full DC inverter system, inverter compressor + DC external fan + inverter water pump. Leading in the energy
efficiency industry, the highest SCOP=5.2(A+++), far exceeding the EU energy efficiency standard by 14.4%
3. Wide ambient temperature and water temperature operation ranges
4. Floating water temperature control more comfort
Changes in outdoor air temperature, changes in heat required indoors, But fix water temperature, provide
constant heat, overheating, waste
5. Long piping length
Maximum piping length for outdoor unit and hydronic box -- 50m, see amend table below
Minimum piping length for outdoor unit and hydronic box -- 3m
Maximum piping height difference for outdoor unit and hydronic box -- 20m
When the water tank is connected,
Maximum length between the 3-way valve and hydronic box -- 3m
Maximum length between the water tank and hydronic box -- 10m