EasyManua.ls Logo

AUX Europe Series User Manual

AUX Europe Series
174 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Service manual
Europe Series
(DC Inverter 1 Drive 1 50Hz R32)
ΑΓΗΝΩΡ A.E.
ΟΜΙΛΟΣ ΕΤΑΙΡΙΩΝ ΤΟΥΡΝΙΚΙΩΤΗ
ΓΕΝΙΚΟΙ ΑΝΤΙΠΡΟΣΩΠΟΙ
Question and Answer IconNeed help?

Do you have a question about the AUX Europe Series and is the answer not in the manual?

AUX Europe Series Specifications

General IconGeneral
BrandAUX
ModelEurope Series
CategoryInverter
LanguageEnglish

Summary

Part1 General Information

Nomenclature

Explains model naming conventions and coding system.

Unit Appearance

Showcases visual models and types of indoor and outdoor units.

Part2 Features

Outdoor Units

Details key features of outdoor units, including refrigerant and efficiency.

Four-way Cassette

Highlights advantages of four-way cassette indoor units.

Ceiling Floor

Describes features of ceiling and floor mounted indoor units.

Constant Duct

Explains constant airflow and control board integration in duct units.

Part3 Piping System

Part4 Specification

Cassette

Technical specifications for cassette indoor units (12K-36K).

Ceiling Floor

Technical specifications for ceiling/floor indoor units (18K-36K).

Duct

Technical specifications for duct indoor units (18K-36K).

Outdoor Unit

Technical specifications for outdoor units (12K-30K).

Part5 Dimension

Cassette

Dimensional drawings for cassette indoor units (12K, 18K).

Ceiling Floor

Dimensional drawings for ceiling/floor indoor units (18K-60K).

Duct

Dimensional drawings for duct indoor units (18K-30K).

Outdoor Unit

Dimensional drawings for outdoor units (12K-60K).

Part6 Electrical Principle Diagram

Cassette

Electrical diagram for cassette indoor units.

Ceiling Floor

Electrical diagram for ceiling/floor indoor units.

Duct

Electrical diagram for duct indoor units.

Outdoor Unit

Electrical diagram for outdoor units.

Part7 Capacity Amendment

Operation Range

Specifies voltage and ambient temperature operating limits.

Capacity Amendment of Different Ambient Temperature

Provides coefficients to adjust capacity based on ambient temperature.

Long Piping Length

Details specifications and cautions for extended piping lengths.

Capacity Amendment of Different Piping Length

Offers capacity adjustment coefficients for height differences.

Equivalent Pipe Length Conversion

Explains converting pipe bends/loops to equivalent straight pipe length.

Part8 Static Pressure Curve

18K Duct

Static pressure curves for 18K duct units.

24K Duct

Static pressure curves for 24K duct units.

30K Duct

Static pressure curves for 30K duct units.

36K/42K Duct

Static pressure curves for 36K/42K duct units.

48K/60K Duct

Static pressure curves for 48K/60K duct units.

Part9 Control

Controller

Details available remote and wired controllers for indoor units.

Parameters Setting

Guides on setting indoor unit parameters via controllers.

Room Card Function

Explains the optional room card functionality and setup.

Wifi Module

Covers WiFi module installation, configuration, and app usage.

Part10 Explosive View

Cassette

Exploded views for cassette indoor units.

12K, 18K Cassette

Exploded view for 12K/18K cassette indoor units.

24K Cassette

Exploded view for 24K cassette indoor units.

36K-60K Cassette

Exploded view for 36K-60K cassette indoor units.

Ceiling Floor

Exploded views for ceiling/floor indoor units.

Duct

Exploded views for duct indoor units.

Outdoor Unit

Exploded views for outdoor units.

Part11 Installation

Preparation

Lists required spare parts and tools for installation.

Precaution

Safety and location precautions for unit installation.

Cassette Installation

Installation procedures for cassette indoor units.

Ceiling Floor Installation

Installation procedures for ceiling/floor indoor units.

Duct Installation

Installation guidelines for duct indoor units.

Outdoor Unit Installation

Installation requirements and spacing for outdoor units.

Connection Piping Installation

Covers piping specifications, selection, and connection.

Emptying or Vacuum

Procedures for vacuuming and emptying the system.

Insulation

Guidelines on pipe insulation methods and materials.

Additional Refrigerant Charge

Instructions for adding refrigerant based on pipe length.

Electrical Connection

Precautions and specifications for electrical wiring.

Part12 PCB Instruction

Outdoor Unit PCB

Identification of components on outdoor unit PCBs.

Indoor Unit PCB

Identification of components on indoor unit PCBs.

Part13 Trouble Shooting

Failure Code Display

Lists and describes error codes for unit failures.

Failure Analysis

Troubleshooting guide for communication failures.

Related product manuals