AVANTI SERVICE LIFT
Installation and Maintenance Manual
Model Service Lift DOLPHIN A-V164
Original instructions
®
AT00014349_Dolphin A-V164_Maintenance and Installation Manual E01R03.indd 1 6/11/2018 2:03:51 PM

Questions and Answers

  • J
    Jeffrey PerezAug 8, 2025
    What to do if Avanti Lifting Systems service lift won't go up or down?
    • A
      Andrew ThomasAug 8, 2025
      If your Avanti Lifting Systems service lift is not moving in either direction, several factors could be at play. First, check if the EMERGENCY STOP button has been activated and reset it by pulling or turning. A power failure could be the cause; ensure the main switch is ON, check the grid voltage, and inspect the supply cable, fuses, and wiring from the control box. Also, verify that no safety switches have been triggered, such as the emergency top limit switch or open sliding doors. If equipped, confirm the trapped key is present and in the ON position. Finally, there might be an obstacle blocking the lift's path; carefully remove it and inform your supervisor. If overheating is the issue, test/repair fuses, supply and connection and clean the motor cover.
  • A
    adam53Aug 12, 2025
    Why does my Avanti Lifting Systems service lift go down but not up?
    • K
      Karen SloanAug 12, 2025
      If your Avanti Lifting Systems service lift only goes down but not up, the problem might be due to several reasons. Check for any obstructions that might be blocking the lift's upward movement and carefully remove them. Ensure that the service lift is not overloaded, as this can prevent it from going up. Inspect the top limit switch to see if it's defective, not connected, or activated; test the connection/function and descend the lift to release the switch if necessary. Also, verify that no phase is missing by testing the fuses and power supply. A fault in the UP control circuit may also be the cause; test and repair connections, wiring and relays.
  • W
    Wendy HumphreyAug 20, 2025
    Why is there loud noise and/or smoke coming from my Avanti DOLPHIN A-V164 Lifting Systems hoist motor?
    • D
      donald88Aug 20, 2025
      If you notice loud noise and/or smoke coming from the hoist motor of your Avanti Lifting Systems, it indicates that the brake is closed or partially closed. Immediately stop work and call your supervisor for advice and potential repair of the hoist, because damage of hoist brake may lead to brake function lost.
  • R
    Robert PageAug 25, 2025
    Why is my Avanti Lifting Systems motor humming loudly or wire ropes squeaking?
    • J
      Jorge MaloneAug 26, 2025
      If the motor hums loudly or the wire ropes squeak on your Avanti Lifting Systems, but the lift still operates in both directions, it indicates that the wire ropes are dirty. If possible, immediately replace the traction hoist and return it for test/repair at AVANTI, because further use of lift may result in damage to the traction wire rope.
  • B
    bwoodardAug 29, 2025
    Why does my Avanti DOLPHIN A-V164 go down when pressing the up button?
    • B
      bennettsarahAug 29, 2025
      If your Avanti Lifting Systems service lift descends when you press the UP button and ascends when you press the DOWN button, it means that two phases are changed in the supply. Have an electrician switch the 2 phases in the plug.
  • C
    Colton RobertsSep 2, 2025
    How to fix a lamp not lit on Avanti DOLPHIN A-V164?
    • J
      James DaviesSep 2, 2025
      If the lamp is not lit on your Avanti Lifting Systems, even though the operation is normal, it is likely that the lamp is defective. Have an electrician replace it.
  • C
    Carol DixonNov 15, 2025
    What to do if Avanti Lifting Systems service lift goes up but not down?
    • L
      laura35Nov 15, 2025
      If your Avanti Lifting Systems service lift only goes up but not down, first check for any obstructions that might be preventing the lift from descending and carefully remove them. If the fall arrest device is holding the service lift on the wire rope, take the service lift upwards to relieve the safety wire rope, open the fall arrest device by pressing the handle, and test its function. Also, a fault in the down controller circuit might be the cause; insert brake lever into the traction hoist and lower lift manually. Inspect the bottom stop switches to see if they are defective, not connected, or activated; test the connection/function and descend the lift to release the switches if necessary. Finally, there might be an obstacle below the service lift, evacuate the service lift and inform...