AVE GRID - VERSIONS; STANDARD; WITH TIMER (over-run); WITH HUMIDISTAT & TIMER

AVE GRID
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6
STANDARD
ThefanisoperatedusingaseparateON/OFFswitchorviaalightswitch(Fig.13A).
Theautomaticshuttersopenafewsecondsafterthefanison.
WITH TIMER (over-run )
Thefanisprovidedwithatimercircuitwhichisadjustablefromabout1minutetoabout
25minutesviatrimmer(Fig.14B).
Operation:connectedaccordingtothediagraminFig.13B,afterthelightisswitchedon,
thefanactivateswithadelayofmax1.5seconds.Afterthelightisswitchedoff,thefan
continues to function for a pre-set period of time.
WITH HUMIDISTAT & TIMER
Thefanisequippedwithahumiditydetector,whosethresholdisadjustablefrom50%
to95%RelativeHumidity,andwithatimerwhichisadjustablefromabout1minuteto
about25minutesviacorrespondingtrimmer(Fig.14C).
TurnthetrimmerHYcompletelyclockwiseandthehumidistatfunctionisdeactivated.
Automatichumidistatoperation:connectedaccordingtothediagraminFig.13C,when
the percentage of Relative Humidity exceeds the pre-set intervention threshold, the
fanstartsupautomatically.WhenthepercentageofRelativeHumiditygoesbelowthe
threshold,thefancontinuestofunctionforapre-setperiodoftime.
Operationwithswitchconnection:connectedaccordingtothediagraminFig.13C,after
thelightisswitchedon,thefanactivateswithadelayofabout1.5seconds.Afteritis
switchedoff,thefancontinuestofunctionforapre-setperiodoftime.
Attention: When the relative humidity level is higher than the pre-set threshold,
automaticoperationwithhumidistathaspriorityovermanualoperation,orratherthefan
cannotbestoppedviaswitch.
VERSIONS