Do you have a question about the Avocent ACS 6000 and is the answer not in the manual?
Type | Serial Console Server |
---|---|
Network Interface Count | 2 |
Ports | 48 serial ports |
Network Interface | Dual Gigabit Ethernet ports |
Power Supply | Dual, redundant power supplies |
Dimensions | 1U rack-mountable |
Management | Web-based, CLI, SNMP |
Security | SSH, SSL, RADIUS, TACACS+, LDAP |
Protocols | SSH, Telnet |
Authentication | Local, RADIUS, TACACS+, LDAP |
Form Factor | 1U rack-mountable |
Upgrade of Apache from v2.2.17 to v2.2.20 to address CVE-2011-0419 and CVE-2011-3192.
ACS 6000 uses an embedded FIPS 140-2 validated module for enhanced security.
Includes 'My Computer' option for file transfer, enhancing firmware and configuration management.
New events for FIPS module status, including OpenSSL self-test failures.
Administrator can configure login banners for Telnet, SSHv2, OBWI, and console sessions.
New attribute for group authorization to configure session idle timeout.
Allows entire unit configuration retrieval over Bootp/TFTP during boot.
Supports regular expressions in the configuration of strings for alert features.
Configure different networks per interface with a default gateway for each.
Includes fixes for Linux permissions, control characters, and serial port alias availability.
Addresses issues with bonding, IP alias, SNMPTRAP messages, and save/restoreconf commands.
Includes fixes for Telnet Send Break, CLI interactive mode, SNMP community names, and logging configuration.
DSView authentication type does not function when the FIPS module is enabled.
Restrictions apply to multi-selection and status updates during PDU firmware upgrades.
Wireless LAN devices, including PCMCIA cards and USB adapters, are not supported.
NIS, IPSec, and NFS data logging features are supported exclusively over IPv4.
Outlet table under PDU Devices is not auto-refreshed after cycle actions.
Session-related configuration changes are effective only upon the next login.
To use keys in SSH sessions, authentication type must be configured as local.
Auto Discovery and Auto Answer options in CAS Profile are mutually exclusive.
Maximum polling interval for SPC power devices and Server Technology PDUs is 20 seconds.
The paste configuration from list_configuration command has a character limit of 80477.
PPP configuration via OBWI/CLI fails on the first attempt, requiring re-configuration.
PM firmware v1.9.2 does not recognize 'currseg'; chain of PDUs must have uniform versions.
Event # 308 for PDU Firmware Upgrade Result is not generated for Avocent® PM.
OTP Auto Refresh fails to restart sequence numbers for OTP users.