20.00kg on the weighing hook, and press Z/T when
the weight has steadied.
4. Thedisplaywillash“PASS”thenreturntonormal
weighing mode. Adjustment is complete!
X. Troubleshooting
• Problem: Scale will not turn on
• Solution: Check the batteries and battery contacts.
• Problem: Displayedweightuctuatesrandomly
• Solution: Make sure to hold the device as still as
possibleorhangitfromaxedpoint.Insomecases,
nearby radio wave emitting devices can cause
uctuations.
• Problem: Displayed weight is inaccurate
• Solution: Perform a calibration adjustment. If
you are still having trouble, contact our warranty
department.
XI. Error Codes
1. OUTZ - Zero point has drifted out of the acceptable
range. Try to perform a calibration adjustment. If the
problem persists, the load cell may be permanently
damaged due to overloading.
2. EEEE - Overload. The maximum capacity has
been exceeded. Remove the extra weight to avoid
permanently damaging the load cell.
3.