Step Parameter mark description Parameter mark
Operation manual
9
Normal display
Press
/A-ADJkey about 3 sec,into DZERO adjustment page
9-1
DZERO(Display Zero Adjust
)Default=0
1.Adjustment display zero with
or
key
2.Press
key enter data and into DSPAN adjustment page
9-2
DSPAN(Display Span Adjust
)Default=0
1.Adjustment display span with
or
key
2.Press
key enter data and return normal display
Step Parameter mark description Parameter mark
Operation manual
10
Normal display
Press
/A-ADJkey about 3 sec,into AZERO adjustment page
10-1
AZERO(Analog Output
Zero Adjustment page)
Value on EEPROM reset=0
1.Adjustment analog output zero with
or
or
key(±9999)
2.Press
key enter data and into ASPAN adjustment page
10-2
ASPAN(Analog Output
Span Adjustment page)
Value on EEPROM reset=0
1.Adjustment analog output span with
or
or
key(±9999)
2.Press
key enter data and return normal display
Appendix
Error Mark Description
Error Mark Analyze & Description
1 Input over error detect
Input signal over range(120%)
2 Input under error detect
Input signal under range(-20%)
3
Display over error detect
Display over range(19999)
4
Display under error detect
Display under range(-19999)
5 A/D Converter error
detect
1.
Input signal over range (180%)
2.
Inside circuit damage
Please moving input signal if still display ADER,please
contact us
6 EEPROM error detect
1.External interference when EEPROM read/write
2.EEPROM write over 100 million times(guarantee 10 years)
Please power reset,if still display E-
step:
1.
E-00 & No alternate display for inquire reset EEPROM
2.
Decide Yes with
or
key,press
display
3.EEPROM was reset,Please follow step 1~10 set again