Section 5: Using the AXIS 200+ AXIS 200+ Users Manual
60
This table lists the CGI parameters for input/output operations
CGI Parameter
Summary
This table summarizes the available CGI parameters:
Parameter/Syntax Description Values
dataout=<string>
Writes the specified data string to
the serial port. Maximum 128 bytes.
Hexadecimal coded
bytes {0, 1, 2, 3, 4, 5, 6,
7, 8, 9, A, B, C, D, E, F,
a, b, c, d, e, f}
read=<n>
Reads the specified number of bytes
from the serial port. The returned
value will be hexadecimal coded and
placed between #’s, e.g. #3A#.
1 ... 128
wait=<n>
Waits the specified number of
seconds before reading from the
serial port. Used together with the
“read” parameter.
1 ... 9
flush=<value>
Empties the input buffer for the serial
port. Always performed first when
combined with other parameters.
yes/no
Parameter/Syntax Description Values
Compression/
compression=<value>
Adjusts the image
quality and file
size.
medium/high/low
Color/
color=<value>
Selects color or
grayscale image.
normal/none
AXIS Logo/
axislogo=<value>
Shows/hides the
Axis logotype.
off/on
Clock/
clock=<value>
Shows/hides the
timestamp.
off/on
Rotation/
rotation=<value>
Rotates the image.
normal/upsidedown/90deg/ 270deg
Mirror/
mirror=<value>
Mirrors the image
horizontally.
off/on