RequirementsforCompliancewithUL2946thEdition
Thissectioncontainsinformationandinstructionsrequired
forULcompliance.TomakesuretheinstallationisUL
compliant,followtheinstructionsbelowinadditiontothe
generalinformationandinstructionsprovidedthroughout
thisdocument.Incaseswherepiecesofinformation
contradicteachother,therequirementsforULcompliance
alwaysreplacegeneralinformationandinstructions.
SafetyInstructions
•TheAxisproductshallbeinstalledandservicedbya
factorytrainedprofessional.
•TheAxisproductshallbeinstalledwithintheprotected
premises(securedarea).
•TheAxisproductshallbemountedindoors.Outdoor
usehasnotbeenevaluatedorapprovedbyUL.
•AllinterconnectingdevicesshallbeULListedandClass
2low-voltagepowerlimited.
•Allwiringmethodsshallbeperformedinaccordance
withNFPA70,localcodesandauthoritieshaving
jurisdiction.
•WhentheAxisproducthasreachedtheendofits
usefullife,disposeofitaccordingtolocallawsand
regulations.Theproductshouldnotbedisposedof
togetherwithhouseholdorcommercialwaste.See
DisposalandRecyclingonpage3.
•Battery
-The3.0Vlithiumbatteryusedby
theAxisproductisaULRecognized
component.(Type:BR2032,
diameter:20mm(0.78in),
manufacturers:Rayovac,
Panasonic).Thefollowingbattery
typeisalsoaULRecognized
component:TypeCR2032,
manufacturers:Fuji,Maxell,
Renata,Varta,Panasonic,JHIH
-Usersshallnotreplacethebattery.
Ifthebatteryneedsreplacing,a
factorytrainedserviceprofessional
shallcontactAxissupport
atwww.axis.com/techsupfor
assistance.
-Usedbatteriesshallbedisposed
ofaccordingtolocallawsand
regulations,whichmayvaryfrom
statetostate.WasteBR/CR
lithiumcellsareneitherlisted
norexemptedfromtheUSEPA
hazardouswasteregulations.Waste
lithiumbatteriescanbeconsidered
reactivehazardouswasteifthereis
asignicantamountofunreacted,
orunconsumedlithiumremaining.
Forinformationabouthowto
disposeofusedlithiumbatteries,
contactyourlocalauthorityfor
wastedisposal.
Specications
•OperatingConditions
-ClassicationIEC60721-4-3Class
3M3
-Temperatures
0°Cto50°C(32°Fto122°F).
-Humidity20–85%RH(non-
condensing)
•Wirearea
-ULListedorR/CAWMwiresthat
haveanconductorgaugerangeof
AWG22–14shallbeused.
-Theminimumconductorgaugefor
connectionbetweenthepower
sourcingequipment(PSE)orpower
injectorandthepowereddevice
(PD)is26AWG.
•Connectors
-Thisproductisnotintendedfor
outsidewiringascoveredbyArticle
800intheNationalElectricalCode,
NFPA70.
-PowerConnector–ForULsecurity
applications,theproductshallbe
poweredbyaUL294Listedor
UL603ListedClass2low-voltage
powerSELVandlimitedpower
supplythatiscapableof4hoursof
standbypower.
-Externalpowertorelays-Ifthe
relaysareconnectedtoanexternal
powersourcethismustbeUL294
ListedorUL603ListedClass2
low-voltagepowerSELVandlimited
powersupplythatiscapableof4
hoursofstandbypower.
-NetworkConnector–Powerover
Ethernet(PoE)shallbesuppliedbya
UL294ListedPoweroverEthernet
IEEE802.3af/802.3atType1Class
3orPoweroverEthernetPlus
(PoE+)IEEE802.3atType2Class4
powerlimitedinjectorthatprovides
44–57VDC,15.4W/30Wand4
hoursofstandbypower.
-CompliancewithIEEE802.3(ator
af)specicationsisnotveriedas
partofUL294B.
-TamperingAlarmPin
Header–Tocomplywith
UL294/7.2.1(Enclosure),the
tamperingalarmshallbeconnected
toasoundalarm.
•SystemConsiderations
-TheAxisproductshallnotimpair
theintendedoperationofthepanic
hardwareusedinconjunctionwith
it.
•WallandCeilingMount
-Ifusingajunctionboxtomountthe
Axisproduct,thejunctionboxshall
beULListed.
•AssignanIPAddress
-ThefunctionalityofAXISCamera
Managementhasnotbeen
evaluatedbyUL.
•MaintenanceInstructions
-Formaintenanceinstructionsand
forinformationabouthowto
conguretheAxisproduct,seethe
UserManual.
•FurtherInformation
-Firmwareversion:NetworkI/O
RelayModule,ModelA9188-VE-
1.0