AP25AFS
Air Filter
AT: 02/05/2023
Code 107709
Original Instructions
• Powerful air filter system for workshops up to 300m³
• Collects dusts “hanging” in the air, improving air quality
• Twin filters, electrostatic outer filter, pleated deep inner filter
• Filtering 98% of all particles 5 microns in size and 85% of all particles 1 micron in size
• Optional charcoal filter for removing odours, organic fumes and pollen
• Three speeds plus timer periods, controlled by remote handset
• Performs at its best when hung from a ceiling
Question and Answer IconNeed help?

Do you have a question about the Axminster PROFESSIONAL AP25AFS and is the answer not in the manual?

Overview

The Axminster Professional AP25AFS Air Filter is a powerful air filtration system designed for workshops up to 300m³. It effectively collects airborne dust, significantly improving air quality in the workspace.

Function Description:

The AP25AFS operates by drawing in air and passing it through a two-stage filtration system. The first stage involves an electrostatic outer filter, followed by a pleated deep inner filter. This dual-filter approach ensures comprehensive removal of particulate matter from the air. The system is designed to be hung from a ceiling, allowing for optimal air circulation and performance. It features multiple speed settings and timer periods, all controllable via a remote handset, offering convenience and flexibility in operation. An optional charcoal filter can be added for enhanced removal of odours, organic fumes, and pollen. The unit also incorporates an 'Active Flow Sensor' which detects when the filters become blocked, alerting the user through an audible alarm and flashing lights on the control panel.

Important Technical Specifications:

  • Motor: 1/5 HP, available in 110-120 V, 60 Hz, 1 Phase or 230-240 V, 50 Hz, 1 Phase.
  • Outer Filter: Filters particles down to 5 microns.
  • Inner Filter: Filters particles down to 1 micron.
  • Filtration Efficiency: 98% of all particles 5 microns in size and 85% of all particles 1 micron in size.
  • Sound Rating: High Speed - 68 dB, Low Speed - 63 dB.
  • Air Flow: High Speed - 1044 CFM, Medium Speed - 702 CFM, Low Speed - 556 CFM.
  • Remote Control: Requires 2 "AAA" batteries (not included).
  • Fuse: 1-amp, 8" fuse, 5-amp (250VAC).
  • Capacitor: 6 MFD 450 VAC.

Usage Features:

  • Control Options: The unit can be operated manually via buttons on the control panel or remotely using the provided handset.
  • Speed Settings: Three speeds are available: high, medium, and low. These can be selected by pressing the "On/Speed" button on either the unit or the remote. An LED indicator on the unit shows the current speed.
  • Timer Function: The remote control allows for automatic shut-off after 1 hour, 2 hours, or 4 hours. This is activated by pressing the "Time" button on the remote.
  • Installation: The air filter is designed to be hung from a ceiling. It requires four eyelet bolts (not included) to be inserted through the ceiling into joists, ensuring secure mounting. The eyelet bolts must be compatible with the unit's Eye Bolt (10) and capable of supporting the system's weight.
  • Power Connection: The unit plugs into a standard electrical outlet. It is crucial to ensure the power cord is unplugged before any adjustments or maintenance.
  • Safety Features: Includes a safety fuse housed on the switch plate. In case of a fuse failure, it can be easily replaced. The unit is designed with grounding requirements, and users are advised to ensure proper grounding to prevent electric shock. Double insulated products are equipped with a polarized plug for added safety.

Maintenance Features:

  • Filter Inspection and Replacement: Both the Filter Net (outer filter) and Inner Filter should be periodically inspected for dirt and debris.
    • Filter Net (1): To access, unlatch the two metal clasps on the rear of the unit. The filter can be cleaned or replaced as needed.
    • Inner Filter (2): After removing the Filter Net, the Inner Filter can be removed and inspected. It can be cleaned with compressed air to remove dirt and debris.
  • Filter Blockage Detection: The 'Active Flow Sensor' alerts the user when filters become blocked through an audible alarm and flashing lights on the control panel.
  • Filter Reset: After cleaning or replacing filters, the system needs to be reset by holding the 'On Speed Button' for approximately 10 seconds.
  • General Inspection: Before each use, inspect the unit for loose screws, misalignment, binding of moving parts, cracked or broken components, or damaged electrical wiring. Any abnormal noise or vibration should be addressed before further use.
  • Remote Control Battery Replacement: To change the two "AAA" batteries in the remote control, remove the back panel, replace the batteries, and then reattach the panel.
  • Service: Product service and repairs should only be performed by qualified personnel using identical replacement parts to ensure safety and prevent electric shock or injury.
  • Cleaning: Keep the work area clean and well lit. Keep the product clean and do not use a damaged product.