Summary

Technical Parameters

Delta Temperature Control

Hysteresis for water temperature regulation; burner restarts when setpoint is reached.

Delta Temperature Waiting Time

Represents the maximum level of water temperature before burner action.

Ignition Attempts

Defines how many times the burner attempts ignition before signaling an error.

Lamp Time

Time the LCD display remains illuminated after no button press.

Enable Second Tank

Parameter to enable the functionality of a second tank.

Switch On External Thermostat

Enables or disables the external thermostat control.

Display Water Temperature

Allows visualization and management of water temperature on the main display.

General Parameters

Maximum Ignition Time

Time limit for ignition; burner stops and signals error if not made.

Flame Stabilizing Time

Wait time after lighting before declaring the burner as operational.

Time Between Cleanings

Interval between automatic cleaning cycles for the combustion grill.

Grill Cleaning Time

Duration of the cleaning process where the fan operates at maximum power.

Alarm Delay

Time delay in the activation of any alarm condition.

Lux Minimum Start-Up

Value the optical sensor must reach to confirm ignition completion.

Lux Turning Off

Optical sensor level that, if not maintained, causes the burner to stop.

Pre Ignition Time Resistance

Time assigned to the resistance to ignite fuel and activate the burner.

External Thermostat Turning Off Time

Waiting time for the burner to turn off when using an external thermostat.

Tim Dead Band Lux

Time the optical sensor must continuously detect above a specified value.

Turning Off Time

Fan operating time at max power after burner shutdown to burn residues.

Alarm Turning Off Time

Fan operating time at max power after alarm shutdown to burn residues.

Tim Fuel Preloading

Regulates the time (seconds) for the initial loading of pellets.

Initial Ventilation

Power of ventilation during the first phase of ignition.

Time Feeder Screw Max

Time between successive loads of pellets.

Feeder Screw Loading Time

Charging time between pellet preload and flame stabilization.

Feeder Screw On Start

Charging time for pellets during flame stabilization.

Feeder Screw Cleaning Time

Auger loading time when it coincides with fan cleaning.

Tim Feeder Screw Power (1-5)

Represents the loading time made by the system for each power level.

Fan Speed On Loading

Represents the fan power (in percentage) during the charge phase.

Fan Speed On Starting

Represents the fan power (in percentage) during flame stabilization.

Fan Speed On Cleaning

Represents the fan power (in percentage) during the cleaning phase.

Fan Speed In Power (1-5)

Fan speed at each power level, dependent on fuel and draft.

Mechanical Cleaning Interval Min

Time between mechanical cleaning operations.

Mechanical Cleaning Forward Sec

Regulates the output of the mechanical cleaning system.

Fan Speed In Feeder Screw

Fan speed on the external auger.

Setting Process

Initial Taring

Process to weigh pellet loading with a balance for calibration.