2
INTRODUCTION
Dear Client,
We would like to thank you for having chosen a
B-Max
appliance.
The model chosen by you, is a high-performance product, with an advanced technological conception, high reliability and
excellent construction quality.
We advise you to entrust the running and maintenance of this appliance to qualified professionals that you know, and also
to use only original spare parts when needed.
This manual contains important guidelines and suggestions which should be complied with in order to obtain a simple in-
stallation and the best possible use of the appliance.
INDEX
SYMBOLS USED IN THE MANUAL AND THEIR MEANING
l
WARNING
To indicate information about particular details.
m
WARNING CAUTION
To indicate information about particularly sensitive details.
a
WARNING DANGER
To indicate actions, which, if not carried out correctly, can cause injuries of a generic kind or can cause malfunc-
tions or material damage to the apparatus; so they require special attention and proper preparation.
f
WARNING DANGER ELECTRICITY
To indicate actions, which, if not carried out correctly, can cause injuries from electricity; so they require special
attention and proper preparation.
d
IT IS FORBIDDEN
To indication actions which MUST NOT be taken.
1 General information 3
1.1 General warnings 3
1.2 Restrictions 3
1.3 Conformities 3
1.4 Structure 4
1.5 Burner description 5
1.6 Safety devices 5
1.7 Size 5
1.8 Accessories 5
1.8.1 Supply feed cochlea: size and weight 6
1.8.2 Pellet container: size and weight 6
1.9 Technical data 6
1.10 Operational wiring diagram 7
1.11 Running 8
1.12 Pellet 8
1.13 Control Panel 9
1.13.1 Viewings on Screen 9
1.14 User parameters 10
2 Installation 11
2.1 Delivery and identification of the product 11
2.1.1 Identification 11
2.1.2 Contents of the package 11
2.2 Handling 11
2.3 Installation location 12
2.4 Mounting the burner 12
2.5 Mounting of the loading cochlea and the pellet
container 13
2.6 Release of exhaust fumes 13
2.7 Electrical connections 13
3 Start-up 14
3.1 Before starting up the burner 14
3.2 First ignition 14
3.3 Checks to carry out after the first ignition 14
3.4 Automatic shut-down and subsequent start-ups 14
3.5 Pellet calibration 14
3.6 Programming of user parameters 15
3.7 List of parameters 17
3.7.1 Technical parameters 17
3.8 Alarm messages 18
3.9 Problems - Possible causes - Solutions 18
4 Maintenance 19
4.1 Periodic maintenance 19
4.2 Disposal 20