Three operation-status LEDs that show power on, sensor
operation, and low battery.
A 20-inch flexible probe.
Simple thumb wheel on/off and gain control allowing one-
handed operation.
A solid-state sensor that has a typical life of 5 years.
A battery capacity of 30 hours under normal use conditions.
The ability to detect natural gas (methane) in concentrations
as low as 20 ppm. In addition, the following gases and vapors
are also detectable:
Introduction
2
Leakator 10
Instruction 19-9167
WARNINGS!
For safety reasons, the Leakator 10 must only be operated
and serviced by qualified personnel. Read and under-
stand the contents of this instruction manual before
operating or servicing.
To prevent ignition of a hazardous atmosphere, do not
perform any maintenance work, such as replacing the
instrument’s batteries, sensor, or sensor-matching resis-
tor, in an area classified as being hazardous.
Industrial Solvents
Paint Thinners
Propane
Naphtha
Acetone
Acetylene
Ammonia
Benzene
Butane
Ethanol
Ethylene Oxide
Gasoline
Hexane
Hydrogen

Other manuals for Bacharach Leakator 10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bacharach Leakator 10 and is the answer not in the manual?

Bacharach Leakator 10 Specifications

General IconGeneral
BrandBacharach
ModelLeakator 10
CategoryGas Detectors
LanguageEnglish