The document describes the Bakbar Swiftgrill Model E92, a commercial electric griddle designed for cooking food directly on its hotplate surface.
The Swiftgrill E92 is an electric griddle that uses thermostatically controlled elements located under the cooking plate to heat the surface. A pilot light indicates when the elements are actively heating. This unit is designed for direct cooking of various food items. The E92 model features two separate controls, one for the left half of the cooking surface and one for the right half, allowing for independent temperature management across the griddle.
The Swiftgrill E92 offers precise temperature control for various food items, with recommended cooking temperatures provided in both Celsius and Fahrenheit:
| Food | Temp (°C) | Temp (°F) |
|---|---|---|
| Meat - Bacon | 180 | 355 |
| Meat - Frankfurters | 180 | 355 |
| Meat - Ham Slices | 180 | 355 |
| Meat - Hamburger Patties | 160 | 320 |
| Meat - Lamb Chops | 190 | 375 |
| Meat - Steak | 200 | 400 |
| Meat - Sausages | 150 | 300 |
| Eggs | 140 | 285 |
| Fish | 190 | 375 |
| French Toast | 190 | 375 |
| Griddle Cakes | 190 | 375 |
| Onions | 180 | 355 |
| Mushrooms | 180 | 355 |
To operate, the user turns the thermostat dial clockwise to the desired temperature. The pilot light will illuminate during heating and extinguish once the set temperature is reached. Turning the dial to higher settings will not decrease the heat-up time. The dual controls allow for different temperatures on each half of the griddle.
Cleaning:
Servicing (DISCONNECT POWER SUPPLY BEFORE SERVICING): Servicing should only be performed after disconnecting the power supply.
Spares: A list of common spare parts is provided. For parts not listed, the model and serial number, along with a description of the required part, should be included when ordering.
| Description | Model E92 Part Number |
|---|---|
| Element 220-240V | 10280 |
| Thermostat | 11987 |
| Knob °C | 15563 |
| Knob °F | 14097 |
| Pilot Light | 13528 |
The document also includes a circuit diagram for both single-phase and two-phase connections, with a specific note for two-phase wiring: "For 2 Phase, connect RH Thermostat to terminal marked L2."