Page 6 55470-01_97_A
DIP Switches and Jumper Definitions
WARNING:
sSetting DIP switches incorrectly may cause abnormal system behavior and/or damage to system components.
sRefer to Switchbank illustration on Wiring Configuration page for correct settings for this system.
sContact Balboa if you require additional configuration pages added to this tech sheet.
DIP Switchbank A Key
A1 ............Test Mode (normally Off)
A2 and A3..........Control amp draw requirements. See Table 1
A4* ............In “ON” position, displays time in 24 hours (military\European time)
............In “OFF” position, displays 12 hour time
A5* ............In “ON” position, displays temperature in Celsius
............In “OFF” position, displays temperature in Fahrenheit
* Sets default for user preferences - only applies when persistent memory is reset (A12 On)
during power-up
A6 ............In “ON” position, Equipment timeout 30 minutes (4 hours for Pump 1 Low)
............In “OFF” position, Equipment timeout 15 minutes (2 hours for Pump 1 Low)
A7 ............In “ON” position, Cleanup Cycle – 30 minutes after spa use/timeout, Pump 1 Low & Ozone run for 1 hour
............In “OFF” position, NO Cleanup Cycle
A8 ...........
In “ON” position, Ozone suppressed for 1 hour after pump or blower button press
...........In “OFF” position, NO Ozone suppression
A9 and A10.........Circ Pump Behavior settings. See Table 2
A11 ............In “ON” position (non-circ mode operation) Pump 1 is two-speed, Ozone is ON
in Filter & Cleanup Cycles only (in any circ mode), Pump 1 is one-speed,
Ozone is ON with Circ Pump
............In “OFF” position (non-circ mode operation) Pump 1 is two-speed, Ozone is
ON with Pump 1 Low
(in any circ mode) Pump 1 is two-speed, Ozone is ON with Circ Pump
A12 ............Persistent Memory Reset (used when the spa is powering up)
DIP Switchbank B Key
B1 ...........In “ON” position, single-speed Pump 2
...........In “OFF” position, two-speed Pump 2
B2 ............N/A
B3 ...........In “ON” position, Blower is enabled
...........In “OFF” position, Blower is disabled
B4 and B8 .........Fiber Optic and Color wheel control; Spa Light Enable
Note: The Light button on an ML900 panel is a SpaLight button. The Light button on most other panels is an EitherLight button.
B5 ...........In “ON” position, Option is enabled - B11 must be OFF
...........In “OFF” position, Option is disabled
B6 ...........In “ON” position, Alternate Panel layout
(ML900 scrunching enabled; ML550 and ML700
Jets 3 replaces Blower)
...........In “OFF” position, Normal Panel layout
B7 ...........In “ON” position, Spa Light operation is On/Off
...........In “OFF” position, Spa Light operation is dimmable
B9 ...........In “ON” position, single-speed Pump 3
...........In “OFF” position, two-speed Pump 3
B10 ...........In “ON” position, Pump 3 enabled (Jets 3 replaces
Light button on Aux panel)
...........In “OFF” position, Pump 3 disabled
B11 ...........In “ON” position, Mister enabled
...........In “OFF” position, Mister disabled
B12 ...........In “ON” position, Mister or Option replaces Blower button on Aux panels
...........In “OFF” position, no button replacement on Aux panels
Jumpers Key
J91 .........Jumper on 1 Pin only enables Real Time Clock function, for use with time capable panels.
Jumper on Pins 1 and 2 will disable RTC function, for use with non-time capable panels.
Table 1 # of Hi-Speed
Pumps/Blower
Before Heat Disabled
A2 A3
OFF OFF 0
ON OFF 1
OFF ON 2
ON ON Up to 4
Table 2 Circ Pump
A9 A10 Behavior
OFF OFF No Circ Pump
ON OFF 24 Hr
OFF ON 24 Hr w/3°F Shut-Off
ON ON Acts like Pump 1 Low
(Filter Cycles, Polls)
B4 OFF
B4 ON
B8 OFF B8 ON
No separately-controlled fiber light; spa light enabled on both
SpaLight and EitherLight buttons; fiber light (not wheel) comes on
with spa light (at any intensity)
No separately-controlled spa
light; fiber light enabled on
both FiberLight and EitherLight
buttons; spa light comes on with
fiber light
Spa light and fiber light each
separately controlled; fiber light
enabled on both FiberLight and
EitherLight buttons; spa light
enabled on SpaLight buttons only