Product Manual
IBVCP1
VIGIL AssureCare
Product Description
VIGIL AssureCare is a sophisticated emergency call-point system, which has been developed in accordance
with BS5839 part 9 and BS5588. The system is a fully monitored and battery-backed communication network,
and has capabilities to function as a Disabled Refuge System, Emergency Help Point System or a simple Call
Point System.
The system has two main components: the Main Control Panel and the Call Point Remote Units. The Main
Control Panel is available in eight options: 16, 32, 48, 64, 80, 96, 112 or 128 way. The panel is normally wall
mounted within a permanently manned main Control Room. There are two versions of Call Point Remote Units
available (red or in stainless steel), which are wall-mounted in areas of risk, such as stairwells, corridors and
‘gathering’ areas.
In an emergency situation, personnel can press the Call button on a Call Point Remote Unit to call and speak
with a Fire Officer or Building Manager. The Fire Officer or Building Manager uses a press to talk telephone
handset at their dedicated Control Panel(s) to control the half-duplex communication with Call Points on an
‘all-call’ or individual basis to relay instructions or to provide reassurance.
Slave Control Panels can be added to the system for control of local zones of Call Point Remote Units (e.g. in
a stairwell), and repeater units are available to extend the cabling distance between the Remote Units.
Manual Contents
Product Description 1
Manual Contents 1
CE Declaration 2
Safety and Precautions 2
Equipment Specifications 2
For the System Designer:
System Cabling Types & Distances And Installation Recommendations 3
For the Equipment Installer:
Equipment Installation 10
For the System Commissioner:
System Commissioning 13
How to Use the Zone Insert Labels 17
For the System Maintainer:
System Maintenance and Expansion 20
Control Panel Indicators and Controls 21
For the System User:
Operator’s Manual supplied separately
Question and Answer IconNeed help?

Do you have a question about the Baldwin Boxall VIGIL AssureCare and is the answer not in the manual?

Baldwin Boxall VIGIL AssureCare Specifications

General IconGeneral
BrandBaldwin Boxall
ModelVIGIL AssureCare
CategoryIntercom System
LanguageEnglish

Summary

Safety and Precautions

ELECTRICAL SAFETY

Essential electrical safety guidelines for installation and use.

System Cabling Types & Distances And Installation Recommendations

Configuration Example 1: 16 Call Point Remote Units

Configuration Example 2:

Configuration Example 3: Typical Connection Diagram Up To 48 Units

Configuration Example 4: Typical Connection Diagram Up To 64 Units

Configuration Example 5:

Recommended Cable Type

Button Allocation

Equipment Installation

System Commissioning

For the System Maintainer

Call Point Remote Unit Fault Identification

Steps to identify faults in remote units and their cabling.

Control Panel Indicators and Controls

Fire Panel Interface