- TWO-STAGE PROGRESSIVE / MODULATING GAS BURNERS WITH ELECTRONIC
CAM "BT 320"
User instructions
manual.
- BRULEUR DE GAZ A DEUX ALLURES PROGRESSIVES / MODULANTES AVEC
CAME ELECTRONIQUE « BT 320 »
Manuel
d’instructions pour
l’utilisation
UK
SP
FR TR
РУС
中文
- QUEMADORES DE GAS EN DOS FASES PROGRESIVAS / MODULANTES CON
LEVA ELECTRÓNICA "BT 320"
Manual
de instrucciones
para el uso.
- "BT 320" ELEKTRONİK KAMLI İLERLEMELİ / MODÜLASYON İKİ
FAZLI GAZ BRÜLÖRLERİ
Kullanım
talimatları kılavuzu.
- ДВУХСТУПЕНЧАТЫЕ ГАЗОВЫЕ ПРОГРЕССИВНЫЕ / МОДУЛЯЦИОННЫЕ
ГОРЕЛКИ С ЭЛЕКТРОННЫМ КУЛАЧКОМ "BT 320"
Руководство
инструкции по
эксплуатации.
-
二段渐进式/电子凸轮”BT 320“调控式燃气燃烧器
使说明

Table of Contents

Other manuals for baltur BGN 250 DSPGN ME

Questions and Answers

  • B
    Benjamin WestAug 11, 2025
    What to do if baltur BGN 250 DSPGN ME Indoor Fireplace goes into lock-out but there is no flame?
    • H
      hpettyAug 11, 2025
      If your Baltur Indoor Fireplace goes into “lock-out” with gas flowing but no flame (red light on), this indicates a fault in the ignition circuit. Here's what you can check: 1. Fault in the ignition circuit: Check the ignition transformer power supply (230V) and high voltage circuit (electrode to earth or isolator broken under locking terminal). 2. Ignition transformer cable discharges to earth: Replace the cable. 3. Ignition transformer cable disconnected: Connect the cable. 4. Faulty ignition transformer: Replace the transformer. 5. Incorrect distance between electrode and earth: Position at the correct distance. 6. Dirty isolator causing electrode discharge to earth: Clean or change the isolator or electrode.
  • E
    Eric GuerreroAug 17, 2025
    How to fix Baltur Indoor Fireplace lock-out with gas flow but no flame?
    • L
      Lisa WhiteAug 17, 2025
      If your Baltur Indoor Fireplace goes into “lock-out”, gas flows out, but there is no flame (red light on), it could be due to: * Incorrect air/gas ratio: Correct the air/gas ratio, ensuring there's not too much air or too little gas. * Gas piping not properly bled of air (for first ignition): Bleed the gas pipe again carefully. * Insufficient or excessive gas pressure: Check the gas pressure value at the time of ignition using a water pressure gauge if possible. * Air passage between disk and head too narrow: Adjust the disk/head opening.
  • V
    Veronica ReynoldsAug 29, 2025
    What to do if my baltur BGN 250 DSPGN ME goes into lock-out but there is no flame?
    • K
      Katelyn SandersAug 29, 2025
      If your Baltur Indoor Fireplace goes into lock-out with gas flowing but no flame (red light on) due to a fault in the ignition circuit, begin by checking the ignition transformer power supply (230V) and the high voltage circuit (electrode to earth or isolator broken under locking terminal). If the ignition transformer cable discharges to earth, replace it. Ensure the ignition transformer cable is connected. If the ignition transformer is faulty, replace it. Correct the distance between the electrode and earth if it's incorrect. If the isolator is dirty, causing the electrode to discharge to earth, clean or change the isolator or electrode.
  • T
    Terri KaiserSep 4, 2025
    How to fix a baltur BGN 250 DSPGN ME Indoor Fireplace that goes into lock-out with no flame?
    • G
      Gregory DavisSep 4, 2025
      If your Baltur Indoor Fireplace goes into lock-out, gas flows, but there is no flame (red light on), it might be due to an incorrect air/gas ratio; correct it, ensuring there is not too much air or very little gas. If it's the first ignition, the gas piping may not have been properly bled of air; bleed the gas pipe again carefully. Insufficient or excessive gas pressure could be the cause; check the gas pressure value at the time of ignition, using a water pressure gauge if possible. Adjust the disk/head opening if the air passage between the disk and head is too narrow.
  • D
    Dr. Beth JohnsonNov 22, 2025
    Why does my baltur BGN 250 DSPGN ME go into lock-out with a red light on?
    • T
      Timothy GrayNov 22, 2025
      If your Baltur Indoor Fireplace goes into lock-out (red light on) due to a fault in the flame control device, several issues could be the cause. It could be due to disturbance to ionisation current from the ignition transformer. In this case, invert the ignition transformer power supply (230V side) and check using an analogue micro-ammeter. The flame sensor might be inefficient, requiring replacement. The flame sensor position may be incorrect; correct its position and check its efficiency with an analogue micro-ammeter. Check the ionisation probe or its earth cable visually and with an instrument. If the flame sensor electrical connection is cut-off, restore it. An inefficient draught or blocked fumes passage could be the cause; ensure the boiler fumes passage and chimney connection are f...

baltur BGN 250 DSPGN ME Specifications

General IconGeneral
CategoryIndoor Fireplace
ModelBGN 250 DSPGN ME
Brandbaltur
IgnitionElectronic
Fuel TypeNatural Gas