EasyManua.ls Logo

Bambi MD75/150 - Preventative Maintenance Schedule; Technical Specifications

Default Icon
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4
Preventative Maintenance
Operation Daily Weekly Monthly Annually
Drain air receiver < 15 Litres •
Drain air receiver > 15 Litres •
Drain filter regulator •
Check oil level •
Change oil •
Replace air intake filter •
Replace filter regulator element •
Check pressure relief activation
•
Above are to be considered minimum frequency
Technical Specification
Type 35 Pump Specification
Voltage 220/240
Motor Kw / Hp 0.37 / 0.5
Frequency Hz 50
Amps 2.4
Watts 340
Displacement l/min 50
FAD@ 6 Bar 33
Type 75 Pump Specification
Voltage 220/240
Motor Kw / Hp 0.5 / 0.5
Frequency Hz 50
Amps 3.6
Watts 500
Displacement l/min 78
FAD@ 6 Bar 54