NOT FOR RESIDENTIAL USE
CANADA: 100% OUTSIDE AIR ONLY
WARNING
Installation must be done by a contractor qualified
in the installation and service of gas-fired heating
equipment or your gas supplier.
Improper installation, adjustment, alteration, service
or maintenance can result in death, injury or
property damage. Read the Installation, Operation
and Service Manual thoroughly before installing or
servicing this equipment.
Installer
Please take the time to read and understand
these instructions prior to any installation.
Installer must give a copy of this manual to the owner.
Owner
Keep this manual in a safe place in order to provide
your serviceman with necessary information.
Bananza
1100 Seven Mile Road NW
Comstock Park, MI 49321
Telephone: +1.616.726.8800
Fax: +1.616.726.8807
Toll Free: 800.255.3416
www.bananza.com
© 2012 Roberts Gordon LLC
WARNING
FOR YOUR SAFETY
If you smell gas:
1. Open windows.
2. DO NOT try to light any appliance.
3. DO NOT use electrical switches.
4. DO NOT use any telephone in
your building.
5. Extinguish any open flame.
6. Leave the building.
7. Immediately call your local gas
supplier after leaving the building.
Follow the gas suppliers
instructions.
8. If you cannot reach your gas
supplier, call the Fire Department.
Fire Hazard
Keep all flammable objects, liquids and
vapors the minimum required clear-
ances to combustibles away from
equipment.
Some objects will catch fire or explode
when placed close to equipment.
Failure to follow these instructions can
result in death, injury or property
damage.
BANANZA
BANANZA
®
B-Series
Direct, Gas-Fired, Industrial
Air Handler
Installation, Operation &
Service Manual
B-350
B-650
B-1000
B-2000
B-3000
B-4000
B-5000
P/N BN121100NA Rev B 10/12

Other manuals for Bananza B Series

Questions and Answers

  • A
    Andrew AvilaAug 12, 2025
    What to do if my Bananza Air Handler motor does not operate?
    • S
      Sarah TaylorAug 12, 2025
      If the motor of your Bananza Air Handler isn't working, there are several potential causes and solutions. First, ensure the main disconnect switch is turned ON. If it is, check for blown fuses in the disconnect or control transformer and replace them, resetting the breaker if necessary (with the disconnect off). Also, verify the wiring between the remote panel and air handler, replacing the switch if needed. Other potential issues include a cool-down timer that doesn't reset (replace the TD4 timer), a defective time delay relay (replace TR1), or a motor starter that isn't operating (replace the starter). Finally, check for a tripped motor overload, resetting it, ensuring the FLA setting is correct, and tightening screws on heater packs or the overload if applicable.
  • C
    christophergloverAug 21, 2025
    How to fix a Bananza Air Handlers blower that does not operate?
    • D
      David MartinAug 22, 2025
      If the blower in your Bananza Air Handler isn't working, begin by checking the belts for breakage or looseness; replace or tighten them as needed. Next, inspect the motor and blower sheaves (pulleys) to ensure they are properly installed and the setscrews are adequately torqued. Lastly, examine the blower bearings to see if they turn freely; replace the bearing(s) if they do not.
  • C
    Colin EatonSep 1, 2025
    Why won't the damper open on my Bananza Air Handlers?
    • J
      jonesamandaSep 1, 2025
      If the damper on your Bananza Air Handler isn't opening, first check for any obstructions. Then, make sure the linkage is tight and secure. Verify that there is 120V at terminal 3B. If these steps don't resolve the issue, replace the damper actuator.