For proper tool performance, the incoming compressed air requirements to the BAND-IT Air
Controller Module of the 3/8” BAND-IT Pneumatic IT Tool must be:
Item Min Max
Inlet Supply Pressure in PSI (kPa) 100 (690) 150 (1,034)
Inlet Supply Air Flow in SCFM (L/min) 1.5 (0.71)
Filtered air particle size (microns) (5)
Air Moisture Content 20% RH
Although cylinders are permanently lubricated, premature wear can be caused by
contaminants in the air supply or the presence of water and oil. The tool’s internal
valves can also be affected by contaminants in the air lines causing a valve malfunction.
The BAND-IT Air Controller Module includes a filter to meet particle requirements.
BAND-IT recommends the use of an Air Booster System to address the potential problems
associated with low air supply, including:
•filters and dries the air supply
•assures pressure of 100 PSI (690 kPa)
Contact BAND-IT-IDEX Customer Service at 1-800-525-0758 or 303-320-4555 for more
information.
Warning - Failure to follow the below specifications may cause significant damage to
internal tool components.
Air System Requirements