The tool has components that must be checked and/or replaced on a regular schedule. If
tools are experiencing difficulties during function or there are audible air leaks coming from
inside the handle, the tool should be returned to BAND-IT for service. Pneumatic components
must be serviced by BAND-IT in order to assure proper tool performance after a repair.
Some applications and environments may require maintenance intervals to be adjusted.
Consult BAND-IT-IDEX for more information.
Preventative Maintenance
For best performance and to extend tool life:
Follow preventative maintenance and parts replacement instructions at appropriate service
intervals.
Do not remove factory applied lubrication from inside tool unless performing a thorough
maintenance procedure and then replacing with fresh lubricant immediately.
Do not use degreaser in the tool body.
Do not spray any lubricant or cleaner into the Quick Connect Air Couplings.
Use nominal recommended tension setting (see “Air System Settings” page). Tension
pressures above the specified settings may cause premature clamp failure and/or tool wear.
For maintenance beyond what is described in this manual, consult BAND-IT-IDEX Customer
Service at 1-800-525-0758 or 303-320-4555 .
Clamps
Installed
Maintenance
Item
Maintenance
Action
Every 25,000
Maintenance Cover (pg. 27) Clean & Re-Lubricate
Tension Block and Gripper (pg. 28) Inspect, Clean, Re-Lubricate
Front Gripper (pg. 29) Clean & Re-Lubricate
Cutter Blade & Blade Screws (pg. 29)
Inspect & Replace if necessary
Every 50,000
Tool Cavity, Tool Head, Linkages (pg. 30) Clean & Re-Lubricate
Knife and Dimple Punch (pg. 31) Inspect & Replace if necessary
Every 100,000
Head Pin and Front Cutoff Lever Inspect & Replace if necessary