Part 1 Operation

The Gas-Explorer Detectors

Details models, gas detection capabilities, alarm symbols, and factory set limits for the detectors.

Essential Operating Practice

Covers basic operation, pump checks, filter importance, zero checks, and test/calibration for reliability.

Operational Description

Explains the instrument's startup sequence, backlight functionality, and how to turn the device off.

Operational Modes

Describes the Monitor, Track Gas, Bar Hole, and Purge modes for effective gas detection.

Instrument Checks

Details automatic sensor/pump checks, connection integrity, and automatic zeroing procedures for device function.

Interference From Other Gases, Liquids, or RFI

Explains how external factors like other gases, liquids, and radio frequency interference can affect sensor readings.

Change of Batteries

Provides essential, step-by-step instructions for safely and correctly replacing the instrument's batteries.

Probes

Lists and describes various probes available for different sampling applications, such as gas leaks or flue gas.

Routine Maintenance

Covers essential maintenance tasks for filters, water-stoppers, and other components to ensure longevity.

Appendix 1

Main Sequences for Operation Modes

A flowchart illustrating the main sequences for operating the instrument in various modes.

Part 2 Setup, Calibration and Alarm Level Selection

Setup Parameters

Explains how to configure basic device settings like alarm limits, bar-hole time, and air-free CO mode.

Further Setup Parameters

Details advanced configuration options including calibration due time, pump tests, and new sensor installation.

Calibration

Describes the A-CAL calibration process, sensitivity checks, and specific sensor calibration procedures.

Part 3 The USB Interface

Downloads

Explains how to transfer data such as readings, calibration, and unit settings to a PC using the USB interface.

Reports

Details the process of generating and viewing various reports like readings, GPS data, and calibration history.

Maintenance

Covers managing instrument settings, user names, detector status, and administrative functions via the interface.

Part 4 Maintenance

Sensor and Pump Installation

Provides a detailed step-by-step guide for installing new sensors or the pump assembly into the instrument.

Accessories and Spare Parts

Bascom_turner GAS-EXPLORER II EGI-201 Specifications