This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). All rights in-
cluding translation reserved. Reproduction by any method, e.g. photocopy, microlming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication
represent the technical status at the time of printing.
Copyright 2020 by Conrad Electronic SE. *2268546-8_v2_1120_02_dh_m_en
Care and cleaning
• Before cleaning the heater, check that it is disconnected from the mains and ensure that it
has cooled down to room temperature.
• Do not clean the heater with water, as this may cause an electric shock. Do not immerse
the heater in water!
• Use a damp, lint-free cloth to clean the exterior casing. If the heater gets wet, leave it to dry
out completely before using it again.
• Use a vacuum cleaner to remove dust that accumulates on the air outlet.
• Never use aggressive detergents, rubbing alcohol or other chemical solutions, as these
could damage the casing or cause the product to malfunction.
Disposal
Electronic devices are recyclable waste and must not be disposed of in the house-
hold waste. At the end of its service life, dispose of the product in accordance with
applicable regulatory guidelines. You thus fulll your statutory obligations and con-
tribute to the protection of the environment.
Technical data
Input voltage ................................. 230 V/AC, 50 Hz
Rated power ................................. max. 2000 W
Switch position I: 1000 W
Switch position II : 2000 W
Recommended room size ............. 16 m
2
Protection class ............................ II
Adjustable thermostat ................... yes
Protection ..................................... Overheat, tip-over
Important: Item no. 2268548 does not have tip over protection.
Cable length ................................. 1.5 m
Operating conditions ..................... -4 to +30 ºC, 10 – 90 % RH (non-condensing)
Storage conditions ........................ -10 to +35 ºC, 10 – 90 % RH (non-condensing)
Dimensions (W x H x D) ............... Item no. 2268546: 20.5 x 12 x 25 cm
Item no. 2268547: 20.5 x 29 x 16 cm
Item no. 2268548: 23.5 x 23.5 x 11 cm
Weight .......................................... Item no. 2268546: 795 g
Item no. 2268547: 1170 g
Item no. 2268548: 1065 g
Model identier(s): Item No. 2268546 (AF501), Item No.: 2268547 (AFB801), Item No.: 2268548 (AF901)
cfvvv Item Symbol Value Unit Item Yes / No
Heat output Type of heat input, for electrical storage local space heaters only (select one)
Nominal heat output P
nom
1.962 kW Manual heat charge control, with integrated thermostat N/A
Minimum heat output (indicative) P
min
1.0 kW Manual heat charge control with room and/or outdoor temperature feedback N/A
Maximum continuous heat output P
max,c
1.962 kW electronic heat charge control with room and/or outdoor temperature feedback N/A
Auxiliary electricity consumption Fan assisted heat output N/A
At nominal heat output el
max
N/A kW Type of heat output/room temperature control (select one)
At minimum heat output el
min
N/A kW Single stage heat output and no room temperature control No
In standby mode el
sb
N/A kW Two or more manual stages, no room temperature control No
With mechanic thermostat room temperature control Yes
With electronic room temperature control No
With electronic room temperature control plus day timer No
With electronic room temperature control plus week timer No
Other control options (multiple selections possible)
Room temperature control, with presence detection No
Room temperature control with open window detection No
With distance control option No
With adaptive start control No
With working time limitation No
With black bulb sensor No
Contact Conrad Electronic SE (Klaus-Conrad-Str. 1, D-92240 Hirschau)