Charging Times
Part
Number
Max
Charge
Rate
(amps)
Deep Cycle
Automotive
(max recommended sizes)
Charge
Time*
Charges
(Min-Max)
Maintains
(max)
Charges (Min-
Max)
Maintains
(max)
MCU025 2.5 7-40 AH 60 AH 80- 250 CCA 650CCA 4-24 hrs
MCU080 8.0 60-100 AH 200 AH 300-700 CCA 1000 CCA 4-24 hrs
MCU120 12.0 80-160 AH 260 AH 480-1100 CCA 2000 CCA 4-24 hrs
*Charge Time depends on state of charge & 'health' of battery.
Specications
Min start up Voltage: 0V
Battery capacity: charges up to 700CCA or 100AH maintains to 1000CCA & 200AH
Input voltage: 185 - 255V / 50 Hz
Charge program: 7 stage pulse
Soft start
Body construction: ABS
Protection: On-board temperature controls
Over temperature protection
Short circuit protection
Reverse polarity protection
Battery types: Gel,Calcium, Sealed Lead Acid (SLA), Wet.
Charging voltages:
GEL LEAD ACID CALCIUM
Charging 14.3V 14.8V 15.6V
Boost 14.8V 15.2V 16.2V
Float 13.3V 13.7V 13.7V