Andromeda MAX VAP mod.2009 v1.1 pag. 1 gennaio 2009
INSTRUCTIONS AND MAINTENANCE
MOD. ANDROMEDA MAX VAP mod. 2009
Read these instructions carefully before operating.
Don’t use the machine differently from the following instructions.
1. SPECIFICATIONS
MODEL: ANDROMEDA MAX VAP 2009 ANDROMEDA MAX VAP 2009
(maxi board)
POWER SUPPLY: 400 V ~ + NEUTRAL / 50Hz 400 V ~ + NEUTRAL / 50Hz
TOTAL INSTALLED POWER: W 9140 W 9640
POWER OF IRON: W 800 W 800
BOILER POWER: W 6000 W 6000
BOARD POWER: W 1100 W 1600
SUCTION/BLOWING POWER: 0,5hp. + 0,5hp. 0,5hp. + 0,5hp.
PUMP POWER: 0,7 hp. 0,7 hp.
BOILER CAPACITY: 10 L. 10 L.
IRONING ENDURANCE: CONTINUOUS CONTINUOUS
OPERATING STEAM PRESSURE: 5 BAR 5 BAR
WEIGHT: KG. 112 KG. 115
OVERALL DIMENSIONS: 59x160x94h. cm 59x160x94h. cm
SLEEVE IRONING ARM (OPTION): W 150 W 150
2
nd
IRON (OPTIONAL): W 800 W 800
BRUSH (OPTIONAL): W 500 W 500
MADE IN ITALY
Fig. 1
MAIN SWITCH
COVER
a
c
PEDAL FOR
STEAMING
PEDAL FOR
BLOWING
PEDAL
FOR SUCTION
WATER INLET
HOSE HOLDER
AIR SCOOP FOR
BLOWING ENGINE
AIR DISCHARGE FOR
VACUUM MOTOR
EXHAUST TAP
MANOMETER
PISTOL
SOLENOID VALVE
IRON SOCKET
IRON REST
SOLENOID VALVES
IRON
IRONING ARM
CABLE
SUPPORT
AIR DEVIATION
Question and Answer IconNeed help?

Do you have a question about the battistella ANDROMEDA MAX VAP 2009 and is the answer not in the manual?

Summary

Important Setup Information

Water Connection Requirements

Details the necessary water connection setup including hose specifications and pressure resistance.

Electrical Outlet Requirements

Specifies the need for a protected electrical outlet suitable for the machine's power.

Unpacking and Initial Setup

Opening the Package and Reading Instructions

Instructions for opening the box, removing the machine, and reading the handbook.

Connecting Iron and Cable Support

Procedure for connecting the iron, steam hose, and fixing cables after removing from packaging.

Machine Operating Modes

Stand-by Mode Operation

Describes the stand-by mode, its LED indicator, and its use for accessing the SET menu.

Standard Mode Operation

Explains the standard mode, activated by the start key, for setting ironing functions.

Key Functions in Standard Mode

Temperature Control Keys

Keys for increasing/decreasing ironing board temperature from 0°C to 90°C (or 120°C).

Vacuum Speed Control Keys

Keys for adjusting vacuum speed from 0 (off) to 5 (maximum).

Blowing Speed Control Keys

Keys for adjusting blowing speed from 0 (off) to 5 (maximum).

Accessory On;Off Keys

Keys to turn on/off the boiler, light, steam pistol, steam brush, and irons.

Key Functions in Stand-by Mode

SET Menu Access

Pressing SET and ESC keys simultaneously enters/exits the SET menu.

OK Key for Confirmation

Key to confirm choices made within the SET menu.

Icon Meanings

Boiler and Pump Status Icons

Icons indicating boiler heating, pump operation, and pump blockage.

Board Heating and SET Mode Icons

Icons for ironing board heating status and electronic card SET mode.

Warning and Malfunction Icons

Icons indicating probe malfunction, cover replacement, filter cleaning, and general maintenance warnings.

Boiler Probe and Overheating Icons

Icons for boiler probe cleaning warnings and anomalous boiler overheating.

Connection and Starting Procedure

Connecting Water and Power Supply

Steps for connecting the water supply hose and the power cable to a suitable outlet.

Initial Machine Start-up

Procedure for turning on the main switch, setting mode, and adjusting board heating.

Boiler Pressure and Steam Check

Verifying boiler pressure and performing initial steam release for hoses.

SET and RESET Menu Operations

Accessing the SET Menu

Procedure to enter the SET menu by pressing keys simultaneously.

Exiting the SET Menu

Methods to exit the SET mode, including key presses or waiting.

SET Menu Configurations

Hours of Work and Zeroing

Displays total and partial hours of work; partial hours can be zeroed.

Resetting Warnings

Procedure for resetting warnings like filter cleaning, cover change, or probe cleaning.

Language Selection

Menu option to set the display language for the machine.

Fuse Substitution Procedures

Substitution of Fuses

Instructions for replacing fuses after a short circuit or overload, emphasizing safety.

Substitution of Power Current Fuses

Guidelines for checking and replacing power current fuses located near the electronic card.

Ironing Operations

Basic Ironing Technique

Using the iron with vacuum pedal, anti-sheen shoe, and managing cables.

Thermostat Adjustment for Ironing

Setting the thermostat for dry and steam ironing based on fabric type.

Using Steam, Vacuum, and Blowing Pedals

Operation of pedals for steam, vacuum, and blowing, especially for knitwear.

Operator Risk Categories

Electrical Risks

Identifies dangerous situations related to electrical hazards during operation.

Mechanical Risks

Lists dangerous situations related to mechanical failures or misuse.

Thermal Risks

Highlights dangerous situations related to high temperatures and heat.

Maintenance and Cleaning Procedures

Interventions and Small Repairs

Procedures for customer or service center interventions like part replacements and cleaning.

Cleaning of Water Filter

Step-by-step guide for cleaning the water filter when a warning is displayed.

Cleaning of the Boiler Probe

Instructions for cleaning the boiler probe to remove encrustation.

Compulsory Maintenance and Disposal

Compulsory Periodical Maintenance

Details on mandatory maintenance performed by authorized personnel.

Packing, Storage, and Transport

Guidelines for packing, storing, and handling the machine during transport.

Disposal of Machine Components

Information on proper disposal of machine parts and environmental protection.

Overview

The BATTISTELLA ANDROMEDA MAX VAP (model 2009) is a professional ironing system designed for efficient and high-quality garment finishing. It is manufactured in Italy and comes in two versions: standard and maxi board, offering flexibility for different user needs.

Function Description

The ANDROMEDA MAX VAP is an advanced ironing board with integrated steam, vacuum, and blowing functions. Its primary purpose is to provide a comprehensive solution for ironing various garments, from delicate fabrics to heavy knitwear. The machine features a heated ironing board, a powerful boiler for continuous steam generation, and motors for vacuum and blowing, which aid in drying and shaping garments. It can be used with one or two irons, a steam pistol, or a steam brush, depending on the accessories connected. The electronic control card manages all functions, allowing users to set temperatures, motor speeds, and monitor operational status.

Important Technical Specifications

Power Supply: Both models operate on a 400 V ~ + NEUTRAL / 50Hz power supply. Total Installed Power: The standard model has a total installed power of 9140 W, while the maxi board model has 9640 W. Power of Iron: 800 W for both models. Boiler Power: 6000 W for both models. Board Power: 1100 W for the standard model, 1600 W for the maxi board model. Suction/Blowing Power: 0.5 hp. + 0.5 hp. for both models. Pump Power: 0.7 hp. for both models. Boiler Capacity: 10 L. for both models. Ironing Endurance: Continuous for both models. Operating Steam Pressure: 5 BAR for both models. Weight: 112 kg for the standard model, 115 kg for the maxi board model. Overall Dimensions: 59x160x94h. cm for both models. Optional Accessories: Sleeve ironing arm (150 W), 2nd iron (800 W), brush (500 W).

Usage Features

Installation: Requires a water connection with a pressure resistance of at least 10 ATM (8/13 mm diameter hose) and a protected electrical outlet suitable for the machine's power. It is crucial to clean the water conduit by exhausting a few liters of water before connecting the hose. Operating Modes:

  • Stand-by Mode: Activated when the main switch is turned on (red LED). Allows access to the SET menu for configuring language, maintenance warnings, and other settings.
  • Standard Mode: Activated by pressing the start key. Enables control over ironing functions such as motor speeds, ironing board temperature (adjustable from 0°C to 90°C, or 120°C on steaming models), boiler on/off, light on/off, steam pistol/brush on/off, and iron on/off. Ironing Process:
  • Steam Ironing: Run the iron on garments while pressing the micro-switch and the vacuum pedal. For drying, keep the foot on the vacuum pedal longer. The thermostat should be set to "cotton" position for steam ironing.
  • Dry Ironing: Adjust the thermostat according to the fabric type.
  • Steaming Pedal: Used to provide steam to the ironing board, especially for knitwear. After steaming, immediately use the vacuum pedal to dry the garment. For frequent steaming, it is recommended to connect an air outlet pipe.
  • Blowing Function: A pedal for blowing is available for garments requiring this function.
  • Safety: Always place the iron on its rest when not in use. Ensure cables do not twine or touch the ironing board to prevent short circuits. Never iron garments directly on persons. Water Management: Use only tap water; never add additives. Empty the boiler once a week when it is cold and the plug is disconnected, ensuring pressure is below 0.5 BAR. Always ensure there is water in the water tank (if equipped) or the water tap is on before operating. Electronic Card Warnings: The machine displays warnings for required maintenance (filter cleaning, cover changing) and malfunctions (temperature probe, pump blockage, boiler overheating). These warnings guide the user on necessary interventions.

Maintenance Features

Periodical Maintenance (Customer or Authorized Service Centre):

  • Cover Replacement: Every 700 hours (indicated by an icon). The cover can be washed.
  • Iron Replacement: As needed (refer to Fig. 1).
  • Solenoid Valve Coil Replacement: As needed (refer to Fig. 1).
  • Steam Hose Replacement: As needed (refer to Fig. 4).
  • Water Inlet Filter Cleaning: When the warning icon appears, or more often if water is impure. This involves turning off the water supply, unscrewing the filter plug, cleaning the filter with running water, and reassembling it, checking for leaks.
  • Boiler Probe Cleaning: When the warning icon appears. This involves opening the rear panel, unscrewing the probe, cleaning it with fine-grain scrubbing paper to remove encrustation, and reassembling it, checking for leaks under pressure.
  • Motor Cleaning: Switch off the current, open the rear panel, and clean the inside with compressed air. Compulsory Periodical Maintenance (Authorized Service Centres, Qualified Technicians, or Manufacturer Only):
  • Signaled by a specific icon on the display. Contact the reseller, Authorized Service Centre, or manufacturer for this intervention. The "general maintenance" icon will be reset by authorized personnel after completion. Fuse Replacement:
  • Electronic Card Fuses: Located on the electronic card (Fig. 2). To access, turn off the main switch (position "0") and unscrew four panel screws. Replace with interchangeable fuses of the same performance.
  • Power Current Fuses (400V-32A): Located near the electronic card. Check these if electronic card fuses are intact. Access by turning off the main switch and unscrewing four panel screws. Replace with interchangeable fuses of the same performance. Software Updates: If "SOFTWARE UPDATE NEEDED" is displayed, contact the Authorized Service Centre to update the software. Troubleshooting: In case of anomalous boiler overheating, turn off the main switch, wait for 30 minutes, and restart. If the problem persists, contact the Authorized Service Centre.

The ANDROMEDA MAX VAP is designed for durability, with an expected lifespan of 7 years under normal working conditions (8 hours/day, 5 days/week). Proper disposal of the machine's iron components and other parts is emphasized through the crossed rubbish bin symbol, promoting environmental protection.