TAM 00624 8
DS 100 – 200 03 / 2005
Three-phase synchronous motor, air-cooled English
Electrical connections (comp. Appendix 1)
Main connection Terminal box
Control connection Resolver - 12-pole connector
Fan / built-in fan motor 6-pin connector (unit DA 100)
Fan / added-on standard motor Terminal box, standard motor (unit DA 132 -280)
Brake (optional) Separate connection
Thermal sensor Connection in terminal box
Thermal motor protection (EN60034-11) Thermal sensor KTY84 in stator winding
Winding insulation (EN 60034-1) Insulation class F
Ambient temperature 0°C ... +40°C
Installation (EN 60034-1) = 1.000 m a.m.s.l.
Storage -30°C…+60°C (+ 85°C, comp. Chap. 2.5)
Bearing Rolling-contact bearing with grease lubrication for life
Calculated bearing life 20.000h (tentative value)
Vibration severity (EN 60034-14) Level N
Vibration-resistant to … (to EN 60068-2-6) Radial 3g (20Hz to 55 Hz)
Axial 0.5g (20Hz to 55 Hz)
Holding brake Option
Actual speed encoder Standard: 2-pole Resolver
For further technical values, please refer to the technical documentation that comes with the
product.
Attention! If the electric motor supplied is not a standard version in accordance with the technical
documentation or if special arrangements were contractually agreed, the technical data may differ
to the values stated in these Commissioning and Maintenance Instructions. The supplementary
technical details are available on request.