EasyManua.ls Logo

Baxi Combi 105 HE User Manual

Baxi Combi 105 HE
13 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
© Baxi Heating UK Limited 2005
Baxi Combi 105 HE
Gas Fired Wall Mounted
Condensing Combination Boiler
User’s Operating Instructions
Please keep these instructions safe.
Should you move house, please hand
them over to the next occupier.

Other manuals for Baxi Combi 105 HE

Question and Answer IconNeed help?

Do you have a question about the Baxi Combi 105 HE and is the answer not in the manual?

Baxi Combi 105 HE Specifications

General IconGeneral
TypeCombi
Fuel TypeNatural Gas
Central Heating Output24 kW
Efficiency Rating90%
ErP RatingA
MountingWall Mounted
Dimensions780 x 450 x 345 mm
Central Heating Pressure3 Bar

Summary

Warranty Information

12 Months Free Warranty

Register for a 12-month free warranty for peace of mind.

Annual Service

Recommend annual service for maximum boiler efficiency and comfort.

Benchmark Commissioning Checklist

Ensure checklist is completed for warranty work and keep safe.

Installation and Legislation

Installation, Commissioning, Service & Repair

Must be installed by competent persons following regulations and manufacturer's instructions.

Codes of Practice

Details relevant British and Irish standards for installation and system treatment.

Safety and Warnings

In an Emergency

Instructions on how to isolate the boiler in case of water or gas leaks.

In case of gas leaks

Steps to take if a gas leak is found or suspected.

Servicing your Appliance

Recommends annual servicing by a competent person for safety and economy.

Electricity Supply

States the appliance must be earthed and requires a 230V ~ 50Hz supply with a 3 amp fuse.

Product Introduction

Introduction to Baxi Combi 105 HE

Overview of the Baxi Combi 105 HE boiler features and operation.

Facia Panel Overview

Details the components and indicator lights on the boiler's control panel.

Boiler Operation

Operating the Boiler

Guide on how to start and operate the boiler using the selector switch.

Temperature Control

How to adjust central heating and domestic hot water temperatures.

Flame Failure Reset

Procedure to reset the flame failure neon indicator.

Safety Thermostats

How to reset the safety thermostat if the boiler shuts down.

Boiler Indicators and Protection

Air Flow Monitor

Explains the air pressure sensing device and potential blockages.

Pump Fault or Low Pressure

Identifies neon indicator for pump issues or low system pressure.

Sensor Fault

Identifies neon indicators for hot water or central heating sensor faults.

Pump Protection

Describes the automatic pump operation to prevent sticking.

System Monitoring and Shutdown

Central Heating System Pressure

Details correct operating pressure and fault indications.

To Shut Off the Boiler

Instructions for short and long-term boiler shutdown procedures.

Frost Protection Mode

Explains the frost protection feature and its activation conditions.

Installation Clearances and Checks

Clearances around the Boiler

Specifies minimum required space around the boiler for operation and servicing.

Pre-Contact Checklist

A list of items to check before contacting an installer for a fault.

Boiler Care and Maintenance

Cleaning the Outercase

Instructions for cleaning the painted panels of the boiler.

Servicing and Repair

Emphasizes servicing by CORGI Registered Installer or competent person.

Spare Parts

Guidance on obtaining spare parts after the guarantee period.