Fig.3
IMPORTANT:Whentheselectorswitchisinthe'0'(Off)positiontheelectricalsupplytotheboilerisisolated.
Theboilerwillnotoperateandtheintegraltimerwillrequireresettingoncetheselectorswitchissettoeither
Position(i)orPosition(ii).
3.3FrostProtectionMode
1.Thefrostprotectionmodeisintegraltotheapplianceandfunctionsonlywiththeselectorswitch(seeSection2.1)inthedomestic
hotwaterandcentralheatingposition.Ifthesystemtemperaturefallsbelow5°Cthentheboilerwillfireonitsminimumsettinguntil
aflowtemperatureof30°Cisreached.Furtherprotectioncanbeincorporatedbyusingasystemfrostthermostat.
3.4PumpProtection
1.Withtheselectorswitch(seeSection2.1)ineitherthecentralheatingorcentralheatinganddomestichotwaterposition,thepump
willautomaticallyoperatefor1minuteinevery24hourstopreventsticking.
page9
4.0TechnicalData
4.1DuotecCombi24,28,33&40HEA
ApplianceType C13 C33 C53
ApplianceCategory CATI2H
HeatInputCH (Net) Max Min
24model kW 20.5 7
28model kW 24.7 9
33model kW 28.9 9.7
40model kW 32.8 9.9
HeatInputCH(Gross) Max Min
24model kW 22.7 7.8
28model kW 27.4 10
33model kW 32.1 10.8
40model kW 36.4 11
HeatOutputCH (NonCondensing) Max Min
24model kW 20 6.8
28model kW 24 8.7
33model kW 28 9.4