EasyManua.ls Logo

Baxi luna duo-tec MP+ 1.35 User Manual

Baxi luna duo-tec MP+ 1.35
100 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
A
MP+ 1.35 – 1.50 – 1.60 – 1.70
it
CALDAIA MURALE A GAS A CONDENSAZIONE
Manuale per l’uso destinato all’utente e all’installatore
en CONDENSING GAS WALL-HUNG BOILERS
Instructions manual for users and installers
de (AT) KONDENSATIONS-WANDGASHEIZKESSEL
Gebrauchsanleitung für den Benutzer und Installateur
es CALDERA MURAL DE GAS A CONDENSACIÓN
Manual de uso destinado al usuario y al instalador

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Baxi luna duo-tec MP+ 1.35 and is the answer not in the manual?

Baxi luna duo-tec MP+ 1.35 Specifications

General IconGeneral
MountingWall-mounted
Output35 kW
Energy Efficiency ClassA
Fuel TypeNatural Gas / LPG
Heat ExchangerStainless Steel
Max Central Heating Temperature80 °C
Max Domestic Hot Water Temperature60 °C
Modulation range1:7
EfficiencyUp to 94%
Domestic Hot Water Flow Rate at 35°C Rise14.5 l/min
TypeCombi
Central Heating Flow Temperature Range30°C to 80°C

Summary

Safety Warnings

Description of Symbols

Explains various symbols used in the manual, including danger, warning, and important information indicators.

General Precautions

Energy-Saving Tips

Provides advice on optimizing boiler efficiency and reducing energy consumption for heating and hot water.

Commissioning the Boiler

Adjusting the CH and DHW Flow Temperature

Instructions for setting the heating and domestic hot water flow temperatures via the control panel.

Operating Modes

Guides users on selecting between DHW, DHW & Heating, and Heating Only operational modes.

Faults

Instructions Prior to Installation

Installing the Boiler

Boiler Pump

Details on the boiler pump's operation, modulation, and performance characteristics.

Installing the Flue

Concentric Ducts

Guidance on installing concentric flue and air ducts, including length limitations and bends.

Separate Ducts

Instructions for installing separate flue and air ducts using a splitting kit.

Cascade Ducts

Information on installing boilers in a cascade arrangement using shared flue collectors.

Electrical Connections

Connecting the Room Thermostat

Procedure for connecting a room thermostat to the boiler's terminal block.

Accessories Not Included in the Supply

Details on connecting optional accessories like the Remote Control unit.

Setting Parameters Using the Remote Control

Room Sensor

Configuration steps to enable the room sensor for climate control with the remote panel.

Flow Temperature Modulation

Procedure to adjust flow temperature modulation by disabling a specific parameter.

Initial Ignition - Special Functions

System Gas Extraction Function

Function to eliminate air from the heating circuit after installation or maintenance.

Calibration Function

Procedure to calibrate the gas valve for optimal performance.

Parameters Setting

Gas Valve Calibration

Adjustment and Safety Devices

Annual Servicing

Cleaning the Condensate Trap

Instructions for safely removing and cleaning the boiler's condensate trap.

Cleaning the Heat Exchanger Fumes Side

Detailed steps for cleaning the heat exchanger, including chemical use and safety measures.

Checking the Burner

Procedure for inspecting the burner for damage, checking electrodes, and ensuring proper seating.

Combustion Parameters

Guidance on measuring and checking combustion efficiency and emissions.

Technical Specifications

Technical Parameters

Detailed technical parameters and performance data for the boiler models.

Product Fiche

Summary of key product features and performance data in a standardized format.