ELECTRICAL
SAFETY ANALYZER
WITH PATIENT SIMULATOR
SA-2010S
SA-2010S-INTL SA-2010S-AUS
USER MANUAL
Question and Answer IconNeed help?

Do you have a question about the BC Biomedical SA-2010S and is the answer not in the manual?

BC Biomedical SA-2010S Specifications

General IconGeneral
Operating Temperature10 - 40 °C
IBP Static-10 to 300 mmHg
NIBP Neonate30 - 150 mmHg
BatteryRechargeable
Measurement RangeDevice specific
ResolutionDevice specific
AccuracyDevice specific
Sample VolumeDevice specific
Measurement TimeDevice specific
Power Supply100 - 240 VAC, 50/60 Hz
MemoryYes
Arrhythmia WaveformsSame as ECG Waveforms (as they are ECG arrhythmias)

Summary

Patient Simulator

Available Models

Lists and describes the different regional configurations of the SA-2010S.

Options

Describes optional features such as RS-232 serial communications.

Accessories

Standard Accessories

Lists the accessories included with the SA-2010S unit.

Optional Accessories

Lists optional accessories available for purchase to enhance the SA-2010S functionality.

Analyzer Layout

Key Controls and Indicators

Explains the function of various keys, LEDs, and indicators on the analyzer.

Component Details

Display and Patient Lead Connectors

Explains the LCD display and the universal patient lead connectors.

Function and Load Selection

Details how to select analyzer functions and test loads.

Device Controls and Indicators

Receptacle and Power Controls

Explains controls for the DUT test receptacle and power outlet status.

Patient Lead and Waveform Selection

Details patient lead selection and waveform generation controls.

Analyzer Components

Connectors and Protection

Details various connectors, self-test snaps, and the protective fuse.

Connectivity and Options

Communications Interface

Describes the optional RS-232 communication port for PC interfacing.

Testing Procedures

Test Preparation and Receptacle Check

Guides on test preparation, including receptacle wiring confirmation.

Mains Voltage and Device Current Tests

Explains how to perform Mains Voltage and Device Current measurements.

Earth Resistance and Leakage Tests

Covers Earth Resistance, Earth/Ground Leakage, and Enclosure Leakage tests.

Patient Lead Leakage and Isolation Tests

Details tests for Lead to Earth/Ground Leakage, Lead to Lead Leakage, and Lead Isolation.

Advanced Measurements

Point-to-Point Leakage and Isolation

Explains measuring leakage and isolation current between two points.

Point-to-Point Resistance

Details how to measure resistance between two points.

Patient Simulator Waveforms

Pulse Wave Simulation

Explains simulation of Normal Sinus Rhythm pulses at various BPMs.

Performance Wave Generation

Details Sine, Square, and Triangle wave generation for testing.

Communication Protocol

Communication Port Configuration

Outlines the serial port configuration for PC communication.

Command Syntax and Structure

Explains the command syntax and hierarchical structure for controlling the analyzer.

Command Summary

SA-2010S-R Communication Commands

Provides a summary of commands for configuring and controlling the SA-2010S-R.

Manual Information and Support

Manual Revision History

Lists the revision history and changes made to the user manual.

Limited Warranty Policy

Details the warranty terms and conditions for the SA-2010S.

Specifications

Electrical Measurement Specifications

Lists specifications for Mains Voltage, Device Current, Earth Resistance, and Leakage Current.

Patient Simulator and Electrical Ratings

Outlines patient simulator parameters, line voltage, and DUT capacity.

Physical and Environmental Data

Provides physical dimensions, weight, and operating/storage environmental ranges.

Notes

General Notes

Provides general notes and remarks related to the SA-2010S.

Related product manuals