50
B OPERATING INSTRUCTIONS
Error message on
display
E-02
Connection cable to motor defective or loose
Check the engine connection cable in the engine
compartment
Controller defective
Check connection cable between motor and controller in the
motor compartment. Replace controller if necessary
Error message on
display
E-03
Speed sensor not correctly aligned
Check the alignment of the speed sensor on the engine in the
engine compartment
Speed sensor not properly connected to
controller
Check the connection cable between the speed sensor and
controller in the engine compartment.
Replace controller in the engine compartment
Error message on
display
E-05
Motor overloaded
Check the lubrication and tension of the running mat as
described in the assembly instructions; check for other causes
that could slow down the belt, such as defective rollers or
foreign objects
Replace controller in the engine compartment
Error message on
display
E-07
The emergency stop safety key is not positioned
correctly on the console
Remove and reposition the emergency stop safety key
Emergency stop switch on console defective
No heart rate display
Hand pulse cable not connected correctly
Check cable connection with console
Hand pulse sensors defective
Replacing the hand pulse sensors
Console circuit defective
Chest strap sensors do not transmit signal
Chest strap battery empty
Replacing the chest strap
Use chest strap without coding