75.0066.07 MC-25 20180913 Page 3 of 475.0066.07 MC-25 20180913 Page 3 of 4
MODULE SETTINGS
JUMPER SETTINGS: choice of wet or dry output for RELAY 1
DRY (no voltage/current supplied by time delay) = both jumpers on left and middle pins
WET (voltage/current supplied by time delay) = both jumpers on right and middle pins
supplied voltage = input voltage
DIP SWITCH SETTINGS: hold-open time delay
RELAY 1:
Adjustable from 0 to 7 seconds; red LED
on for duration of time delay set on
RELAY 1; independent of time delay set
on RELAY 1, RELAY 2 activates 0.5 or 1.5
seconds after RELAY 1 begins.
RELAY 2:
Time delay set to RELAY 2 is the hold open time delay
for the door; adjustable from 0 to 15 seconds; green
LED indicates RELAY 2 is active and sending signal to
door control to hold door open.
DELAY OPTION:
Time delay between
Relay 1 being activated
and Relay 2 being
activated.
OFF
ON
7654321
green LED (safety beams)
red LED (lock-out time)
8
RED LED
(RELAY 1 active)
GREEN LED
(RELAY 2 active)
JP1
1
4
BLUE
GREEN
YELLOW
GRAY
ORANGE
GRAY
BROWN
RED
BLACK
PURPLE
DRY OUTPUT ON RELAY 1
BLUE
GREEN
YELLOW
GRAY
ORANGE
GRAY
BROWN
RED
BLACK
PURPLE
JP1
JP2
1
4
WET OUTPUT ON RELAY 1
TIME
DELAY
(sec)
DIP 1
(1 sec)
DIP 2
(2 sec)
DIP 3
(4 sec)
1 ON OFF OFF
2 OFF ON OFF
3 ON ON OFF
4 OFF OFF ON
5 ON OFF ON
6 OFF ON ON
7 ON ON ON
TIME
DELAY
(sec)
DIP 4
(1 sec)
DIP 5
(2 sec)
DIP 6
(4 sec)
DIP 7
(8 sec)
1 ON OFF OFF OFF
2 OFF ON OFF OFF
3 ON ON OFF OFF
4 OFF OFF ON OFF
5 ON OFF ON OFF
6 OFF ON ON OFF
7 ON ON ON OFF
8 OFF OFF OFF ON
9 ON OFF OFF ON
10 OFF ON OFF ON
11 ON ON OFF ON
12 OFF OFF ON ON
13 ON OFF ON ON
14 OFF ON ON ON
15 ON ON ON ON
TIME
DELAY
(sec)
DIP 8
0.5 OFF
1.5 ON