Connect the power, press the ON/OFF button on the remote control to
begin operation.
Press MODE button to select AUTO, COOL, DRY, FAN and HEAT to
check whether the appliance is operating normally or not
If the ambient temperature is lower than 16 °C , the air conditioner
can’t start cooling.

1. Standard length pipe
• 5m, 7.5m, 8m

For the unit with a 5 cm standard connection pipe, there is no min
length for the connection pipe. For the unit with 7.5 and 8 cm standard
connection pipes, the min length of connection pipe is 3 m.

Table 2. Max length of connection pipe Unit: m
Capacity

of connection
pipe
5000Btu/h
(1465W)
15
7000Btu/h
(2051W)
15
9000Btu/h
(2637W)
15
12000Btu/h
(3516W)
20
18000Btu/h
(5274W)
25
Capacity

of connection
pipe
24000Btu/h
(7032W)
25
28000Btu/h
(8204W)
30
36000Btu/h
(10548W)
30
42000Btu/h
(12306W)
30
48000Btu/h
(14064W)
30