• Connect the power, press the ON/OFF button on the remote control to
begin operation.
• Press MODE button to select AUTO, COOL, DRY, FAN and HEAT to
check whether the appliance is operating normally or not
• If the ambient temperature is lower than 16 °C , the air conditioner
can’t start cooling.
1. Standard length pipe
• 5m, 7.5m, 8m
For the unit with a 5 cm standard connection pipe, there is no min
length for the connection pipe. For the unit with 7.5 and 8 cm standard
connection pipes, the min length of connection pipe is 3 m.
Table 2. Max length of connection pipe Unit: m
Capacity
of connection
pipe
5000Btu/h
(1465W)
15
7000Btu/h
(2051W)
15
9000Btu/h
(2637W)
15
12000Btu/h
(3516W)
20
18000Btu/h
(5274W)
25
Capacity
of connection
pipe
24000Btu/h
(7032W)
25
28000Btu/h
(8204W)
30
36000Btu/h
(10548W)
30
42000Btu/h
(12306W)
30
48000Btu/h
(14064W)
30