27
EN
Dehumidier | Deshumidicador | Desumidicador
3
4

Humidity Set Control
The humidity level can be set within a range of 35 % RH (Relative Humidity) to 85
% RH (Relative Humidity) in 5 % increments.
For drier air, press the button and set to a lower percent value (%).
For damper air, press the button and set a higher percent value (%)

Use the Up/Down buttons to set the Auto start and Auto stop time from 0.0 to 24.
5
Fan Control the fan speed. Press to select fan speed in three steps: low, medium
and high. The fan speed indicator light illuminates under dierent fan speed
settings. When selecting the High fan speed, both the Low and Med fan speed
lights illuminate
.
6
Timer Press to initiate the Auto start and Auto stop feature, together with the
and
buttons.
7
 Press this button for 3 seconds to start the Wireless
connection mode. The LED DISPLAY will show ‘AP’ (at this time the unit shuts
o all other functions) to indicate you can set the Wireless connection. If the
connection (router) is successful within 8 minutes, the unit will exit Wireless
connection mode automatically, the Wireless indicator illuminates and the unit
resumes the previous functions. If the connection fails within 8 minutes, the unit
exits the Wireless connection mode automatically
.
8
Display Shows the set % humidity level from 35 % to 85 % or auto start/stop time
(0~24) while setting, then shows the actual ( ±5 % accuracy) room % humidity
level in a range of 30 % RH (Relative Humidity) to 90 % RH (Relative Humidity).
Error Codes and Protection Codes:
AS - Humidity sensor module error - Unplug the unit and plug it back
in. If the error persists, call for service
ES - Temperature sensor error - Unplug the unit and plug it back in. If
the error persists, call for service
P2 - Collector is full or collector is not in the correct position – Empty
the collector and place it in the correct position.