Pin :
19 Altitude pulse B 2
20 Altitude pulse C 4
21 Altitude pulse C 2
22 Altitude pulse C 1
23 Altitude pulse D 4
24 Altitude encoding GND
25 Supply voltage + 10 . . . 32 V DC
C. RS 422 interface
(1) The RS 422 interface enables complete remote control of the transponder,
i.e. all operating functions between the T/R unit and control unit are
transmitted.
(2) The data format of the RS 422 interface is factory-defined and described.
The transmission rate is 4800 Baud.
D. External IDENT push-button
If this input (Pin 1 of unit connector P8) is briefly connected to GND (e.g. by
an external push-button), the IDENT function is started in the same way as
with the IDENT push-button on the front panel.
E. External FUNCTION ON
The transponder can be switched ON and OFF from the control unit using
this input. To do this, Pin 9 of unit connector P8 must be briefly connected
to GND.
INSTALLATION AND OPERATION
ATC 3401 - (1) - R
Page 2-5
34-50-03 June 15/96
UNCONTROLLED COPY IF PRINTED