Questions and Answers

  • A
    Ann HallAug 5, 2025
    What to do if my Bedford B6031I shows a sensor fault?
    • M
      Mallory SmithAug 5, 2025
      If your Bedford Inverter displays a sensor fault, first, examine the cable connecting the pressure transmitter to the controller. Second, verify the sensor's condition to ensure it is functioning correctly.
  • R
    Robert RushAug 12, 2025
    Why is the water pressure low in my Bedford Inverter?
    • L
      Lisa WilliamsAug 12, 2025
      Low water pressure in your Bedford Inverter can stem from several causes: * A faulty sensor. * The motor rotating in the wrong direction. * Insufficient water inflow. * Air trapped inside the pump. To resolve this, check the pressure transmitter installation, ensure the motor rotates correctly, verify parameter b00.09 isn't set too high, and bleed any air from the pump.
  • D
    Dustin BrownAug 19, 2025
    What to do if my Bedford Inverter has high water pressure?
    • M
      Mary GravesSep 12, 2025
      High water pressure in your Bedford Inverter can be due to: * A faulty sensor. * The parameter b00.08 setting value being too small. To address this, check the installation of the pressure transmitter and verify the parameter b00.08 setting.
  • A
    Alicia WeissAug 28, 2025
    What to do if my Bedford B6031I shows a water shortage fault?
    • C
      Christopher LongAug 28, 2025
      A water shortage fault in your Bedford Inverter can occur if there is no water in the deep well or if the water-level sensors in the deep well are broken. Check if there is water in the deep well and inspect the water-level sensors for damage.

Summary

Safety Precautions

Wiring

Main Circuit Terminals Wiring

Details the connections for main circuit terminals for various B6031B2 and B6031ID models.

Control Circuits Terminals Wiring

Illustrates the wiring connections for control circuit terminals and current sensor.

Water-level Auto Controlling Terminals Wiring

Details wiring for deep well water-level sensors, explaining connections to COM, S1, and S2.

Wiring Main Circuits

Details high-performance main circuit wiring, circuit breakers, AC reactors, and EMC filters.

Operation

Instructions of Parameters Group

Application Guidance

Fault and Trouble Shooting

Pump Running Fault and Trouble Shooting

Lists pump running faults (LP, HP, E022, A033) with reasons and solutions.

Controller Running Fault and Trouble Shooting

Details controller faults (E001-E021) including IGBT, over-current, over-voltage, and EEPROM issues.