Programming
To permanently set the time settings, press the Prog button for 1 second. The selection lamp of
the current selection position now flashes, signalling that programming mode has been
reached. The selection and setting is now carried out in the same way as for the foreground
setting, but the time values are now saved in the non-volatile memory after returning to the
basic status or changing the selection. If no further time settings are to be selected, the system
returns to the basic status by pressing the Prog button again or automatically after 5 seconds.
Time setpoints 1-7
As described above, the sequence times can be accessed by pressing the button directly. If
times are to be set and saved permanently, press the Prog button to enter programming mode.
Parameters
Functional description
Setting range
Default value
Customer value
Group Expiry times
S1
Expiry time 1
00:00...99:59 min.
00:30 min.
S2
Expiry time 2
00:00...99:59 min.
00:45 min.
S3
Expiry time 3
00:00...99:59 min.
01:00 min.
S4
Expiry time 4
00:00...99:59 min.
01:30 min.
S5
Expiry time 5
00:00...99:59 min.
02:00 min.
S6
Expiry time 6
00:00...99:59 min.
02:30 min.
S7
Expiry time 7
00:00...99:59 min.
04:30 min.
Parameter level P and A
These parameters can be accessed by pressing the up and down buttons simultaneously for 3
seconds. The name "P1" of the first parameter of the P level then appears. The delay is
intended to prevent unauthorised access. Other P parameters can now be selected by pressing
the up or down button alone. The value of the selected parameter then appears after pressing
the Prog button. It is adjusted by pressing the up or down button in addition to the Prog button.
If you only press the up button for 6 seconds after reaching the last P parameter, an
intermediate stage "PA" appears. Now press the up and down buttons again simultaneously for
3 seconds. The name "A1" of the first parameter of the A level then appears. The setting is
carried out as in the P level.
Note: Due to the one-finger setup, it is possible to accidentally enter the setting mode before
reaching the P level when the up and down buttons are pressed simultaneously. The buttons must
then be briefly released again.