EasyManua.ls Logo

BeF Home BLANZEK 730 AQUA User Manual

Default Icon
9 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
________________________________________________________________________________________________________________________________
Firma: BeF Home, s.r.o. Strana 1 (celkem 9) Platí od: 1. 6. 2007
Vydání: 1
INSTALLATION AND SERVICE INSTRUCTIONS FOR FIREPLACE
INSERTS
BLANZEK 730 AQUA
Important:
Inform your chimney sweep!
Read the complete installation and service instructions!
Keep to the regulations and orders of these instructions during installation and service of this fireplace insert!
Keep to the appropriate standards during fireplace insert installation and service.
Keep these instructions in a safe place!
These instructions contain the Equipment Certificate!
Hot water fireplace insertsBlanzek 730 AQUA EN 13 229 - W
Congratulations!
You have chosen a product of high quality, theBlanzek 730 AQUA hot water fireplace insert. Read carefully these service instructions.
You will get the information about function and operation of your fireplace insert, you will increase its value and its service life. Also you can
save fuel and protect the environment. The Equipment Certificate is included.
We ask you please to read this manual as well as the instructions for your specific model before beginning the installation.
We can provide a guarancy for our products only when the installation and service instructions are kept.
Essential requirements:
§ It is necessary to ensure that the whole unit with connecting pieces and chimney will be safe during operation. The whole unit must be safe
and easy to clean.
§ THE DATA OF SAFETY PRECAUTIONS FROM THE POINT OF VIEW OF FIRE PROTECTION IN ACCORDANCE WITH
ČSN 06 1008
The fireplace insert must be installed, so that all required demands of national technical standards and regulations have been kept. Be
especially careful to maintain a minimum distance from any combustible objects during the fireplace installation.
§ The minimum safe distance from combustible material with combustibility degree of B, C1 and C2 is min. 200 mm. For a combustibility
degree of C3 and for unsubtantiated combustibility degree in accordance with ČSN 73 0823 it is necessary to double the distance.
§ The unit may be used in a normal environment in compliance with national technical standards and regulations. When this enviromnent
changes and there could be a temporary fire or explosion risk (e.g. at work with paint substances, at linoleum mounting, etc.) the unit must
be removed immediately.
§ Note: The hot water fireplace insert must be situated a safe distance from other domestic equipment.
The hot water fireplace insert must not be used without water and it must be connected
with the central heating which ensures adequate heat outlet.
Information about the combustibility level of some combustion materials:
The combustibility level of the construction material
A incombustible – granite, sandstone, concrete, aerated concrete, bricks, ceramics facing
B hardly combustible acumin, heraclit, plasterboard, itaver
C1 hard combustibility leafy wood, plywood, sirkolit, hardened paper, Formica TM
C2 medium combustibility – cork sheet, solodur, india-rubber, floor material
C3 easily combustible – wood-fibre sheets, polystyrene, polyuretane, PVC
Position:
Hot water fireplace inserts can be positioned only in rooms and in places which are risk free. There must not be any electric wires in walls and
in ceilings where a jacketed chimney insert is installed. In rooms where a fireplace insert is situated there must be a sufficient fresh-air inlet for
combustion. The base where the fireplace insert is situated must be made ond must be large enough to permit the firebox to work correctly.
Question and Answer IconNeed help?

Do you have a question about the BeF Home BLANZEK 730 AQUA and is the answer not in the manual?

BeF Home BLANZEK 730 AQUA Specifications

General IconGeneral
BrandBeF Home
ModelBLANZEK 730 AQUA
CategoryIndoor Fireplace
LanguageEnglish

Summary

General Safety and Installation Guidelines

Important Safety Precautions

Crucial safety advice, regulations, and instructions for installation and service.

Fire Protection Data

Safety precautions related to fire protection and minimum distances from combustible materials.

Combustion Material Classification

Details on the combustibility levels of various construction materials.

Installation Position Requirements

Guidelines for selecting a safe and suitable location for the fireplace insert.

Location and Airflow Requirements

Forbidden Installation Locations

Specifies areas where the fireplace insert must not be installed.

Combustion Air Inflow

Requirements and methods for supplying combustion air to the fireplace.

Adequate Chimney Connection

Guidance on connecting the fireplace to a suitable chimney system.

Chimney Parameters

Specifies required chimney dimensions and standards.

Diagrams and Protective Measures

Fireplace Insert Location Diagram

Illustrates the placement and components of the fireplace insert assembly.

Ceiling Protection

Requirements for protecting ceilings from heat and fire.

Floor Protection in Front of Fireplace

Specifies protective measures for the floor area in front of the insert.

Chimney Connection Diagram

Illustrates the connection of the fireplace insert to the chimney.

Central Heating System Integration

Heating System Connection Diagram 1

Illustrates the connection of the fireplace to the central heating system.

Heating System Connection Diagram 2

Shows connection with the main boiler and the fireplace insert.

Connection Notes

Important remarks regarding hot water outlet and cold water inlet connections.

Piping and System Requirements

Main Piping Requirements

Guidelines for main piping design, pressure loss, and valve usage.

Expansion Vessel and Pump

Requirements for expansion vessels and circulating pumps.

Pressure Relief Valve

Specifies the need and settings for a pressure relief valve.

Anti-freeze Mixture Warning

Caution against using anti-freeze mixtures due to toxicity.

Thermostatic Valve Service

Instructions for checking and maintaining the thermostatic valve.

Filling the System with Water

Procedures for filling the system and water hardness requirements.

Brick Veneer and Insulation Requirements

Requirements for brick veneer and thermal insulation for walls.

Insulation and Clearances

Ceiling Protection Details

Specific requirements for ceiling insulation and protection.

Preventative Requirements Table

Lists minimum distances and insulation thicknesses for various components.

Permitted Insulation and Veneer Materials

Permitted materials for thermal insulation and brick veneer.

Fireplace Insert Connection

Guidance on connecting the fireplace insert to the chimney.

Convection Air Holes

Requirements for convection air inlets and outlets.

Convection Cross-Section Distances

Minimum distances for convection airflow between insert and coating.

Assembly and Fire Safety

Convection Air Area Requirements

Specifies the necessary space for convection air.

Fireplace Insert Assembly

Steps for assembling and installing the fireplace insert.

Extension Joint

Requirement for an extension joint between insert and coating.

Coating Materials

Specifies uncombustible materials for the fireplace surround.

Ornamental Beams Placement

Guidelines for the placement of ornamental beams.

Fire Protection in Heat Radiation Area

Minimum distances for fire protection from heat radiation.

Outer Air Input for Combustion

Requirements for the outer air input pipe for combustion.

Suitable Fuel

Information on approved fuel types for the fireplace insert.

Operation and Fire Safety

Fire Protection Above Heat Radiation

Safety distances from combustible materials above heat radiation.

Protection Against Fire Injuries

Precautions to prevent burns and keep children away.

Application and Activation

Guidelines for the correct application and activation of the fireplace.

Acceptable Fuel and Operation

Details on acceptable fuel, its properties, and economical operation.

First Lighting Procedure

Instructions for the initial lighting of the fireplace.

Lighting a Fire

Step-by-step guide on how to start and maintain a fire.

Setting Air Inlet During Standby

How to set the air inlet when the fireplace is not in use.

Fuel Addition and Glass Cleaning

Best practices for adding fuel and maintaining glass cleanliness.

Bedewing and Tarring Prevention

Advice on preventing condensation and tar buildup in the fireplace.

Maintenance and Cleaning

Open Fires Supervision

Emphasizes constant supervision of open fires.

Fuel Addition Limits

Rules for adding fuel to the firebox.

Ash Removal

Instructions for safely removing ash from the fireplace.

Cleaning and Maintenance

Annual or periodic cleaning procedures for the fireplace and flue.