DA3000 Standalone Touch Access Controller
User Manual v2.0
1. Specifications:
1.1 Technical parameters
NO
Item
Value
1
Operating voltage
DC 12V±10%
2
Operating current
< 100mA
3
Dimensions
120mm×78mm×22mm
4
Weight
110g
5
Ambient temperature
0℃—60
6
Relative humidity
20%80%
7
Storage
1000 users
8
Card type
RFID (Mifare optional)
9
Card reading distance
110CM
1.2 Factory Default
1.3 Light and Sound indicates:
Light: red and green
Light Description
Access control status
Red light flash every 1 secSlow flash
Holding state
Red light is always ON
Programming state
Green light is always ON within Open time
Unlocking state
Green light flash every 0.5sec (Fast flash)
Pending further action
Soundbuzz
Description
Indicates
1 short buzz
Valid input
3 short buzz
Invalid input
1 long buzz
Program success
Continuous long buzz
Restoring factory programming passwords
2. Installation Guide:
JP1 terminal
JP2 terminal
NO
Mark
Function
1
+12V
Power+
2
GND
Power-
3
DATA0
WG DATA0
4
DATA1
WG DATA1
5
NC
Relay NC output
6
COM
Relay Com output
7
NO
Relay NO output
NO
Mark
Function
1
+12V
Power+
2
GND
Power-
3
PUSH
Low level output
4
OPEN
Door Release
5
BELL
Bell
6
BELL
Bell
Programming
Password
123456
Common Access
Password
None
Backlight
Auto
Relay Unlock
output
5 Seconds
W26 port
Input
Security mode
OFF
Open mode
Card or Access Password
Access Password include Private Access Password (PIN) and
Common Access Password
Question and Answer IconNeed help?

Do you have a question about the Belco Security DA3000 and is the answer not in the manual?

Belco Security DA3000 Specifications

General IconGeneral
CategoryIP Access Controllers
Input Voltage12VDC
Operating Temperature-10°C to 50°C
Humidity10% to 90% non-condensing
Communication InterfaceTCP/IP

Summary

Access Controller Specifications

Technical Parameters

Details operating voltage, current, dimensions, weight, temperature, humidity, storage, card type, and reading distance.

Factory Default Settings

Lists default programming password, common access password, relay unlock output, backlight, W26 port, and open mode settings.

Indicator Lights and Sounds

Explains the meaning of red/green light flashes and different buzz sounds for various operational states.

Installation Guide

JP1 Terminal Connections

Describes the function of each pin on the JP1 terminal, including power, door release, and bell outputs.

JP2 Terminal Connections

Details the JP2 terminal pins for power, ground, Wiegand data, and relay outputs.

Programming Guide

Detailed Programming Operations

Covers changing passwords, adding/deleting users (card, PIN, common access), and configuring open mode and reader settings.

Factory Reset Procedure

Step-by-step guide to reset the device to its factory programming password.

Manager Card (MAC&MDC) Usage

Explains how to use Manager Add Card (MAC) and Manager Delete Card (MDC) for user management.

User ID Number Explanation

Clarifies that User IDs are auto-generated 4-digit numbers, excluding common access passwords.

Changing User PIN

Provides instructions for changing a user's Personal Identification Number (PIN) when using card + PIN mode.