90
Installation BRS20/22/30/32/40/42/50/52
Release
12
01/2022
7.10 Immunity
7.11 Electromagnetic compatibility (EMC)
Note: Use shielded data cables for gigabit transmission via copper cables. Use shielded data cables for all transmission
rates to meet the requirements according to EN 50121-4 and marine applications.
Immunity Standard applications
a
a. EN 61131-2, CE, FCC – applies to all devices
Navy applications Railway applications
(trackside) as per EN 50121-4
IEC 60068-2-6, test Fc Vibration 5 Hz ... 8.4 Hz with 3.5 mm
(0.14 in) amplitude
2 Hz ... 13.2 Hz with 1 mm
(0.04 in) amplitude
8.4 Hz ... 200 Hz with 1 g 13.2 Hz ... 100 Hz
with 0.7 g
IEC 60068-2-27, test Ea Shock 15 g at 11 ms
Table 25: Immunity
EMC interference emission Standard applications
a
a. EN 61131-2, CE, FCC – applies to all devices
Navy applications Railway applications
(trackside) as per EN 50121-4
EN 55032 Class A
DNV Guidelines EMC B
FCC 47 CFR Part 15 Class A
EN 61000-6-4 Fulfilled Fulfilled
Table 26: EMC interference emission