Accessories
Too
l-
06
8
mm
a
n
d
1
0
mm wr
e
n
ch
4
3442-00001 Gland (needed for additional wires
)
1
1
09
7-
0000
1 Gasket for Gland (needed for additional wires
)
NOTE
:
When using AFBUP N4(H), AFBUP-S N4(H), AFXUP N4, AFXUP-S N4 actuators, only use
a
ccessories listed on this pa
g
e.
For actuator wiring information and diagrams, refer to Belimo Wiring Guide
.
Typical Specification
On/Off sprin
g
return damper actuators shall be direct coupled type which require
n
o crank arm and linka
g
e and be capable of direct mountin
g
to a
j
ackshaft up to a
1.05” diameter. The actuators must be desi
g
ned so that they may be used for either
c
lockwise or counterclockwise fail-safe o
p
eration. Actuators shall be
p
rotected
from overload at all an
g
les of rotation. If required, two SPDT auxiliary switch shall
b
e provided havin
g
the capability of one bein
g
ad
j
ustable. Actuators with auxiliary
switches must be constructed to meet the re
q
uirements for Double Insulation so
an electrical
g
round is not required to meet a
g
ency listin
g
s. Actuators shall be
c
ULus A
pp
roved and have a 5
y
ear warrant
y
, and be manufactured under I
SO
9001
International Qualit
y
Control Standards. Actuators shall be as manufactured b
y
Belimo
.
A
FBUP N4
(
H
)
, AFBUP-
S
N4
(
H
)
, AFXUP N4, AFXUP-
S
N4
NEMA 4, On/Off, Sprin
g
Return, 24 to 240 VAC
AFBUP N4(H)
AFBUP-S N4(H)
AFXUP N4
AFXUP-S N4
W
066
_AFBUP_N
4
On/Off Wirin
g
Wht
Blk
AFBUP-S N4(H)
AFXUP-S N4
W067
_
AFBUP-
S_
N
4
Auxiliary
S
witche
s
A
F-NF N4H 12
0
V h
ea
t
er
N
EMA 4 Heater
Wiring Diagrams
1
P
rov
id
e over
l
oa
d
protect
i
on an
d
di
sconnect as requ
i
re
d.
2
C
A
U
TI
O
N
E
qu
i
pment
D
ama
g
e
!
A
ctuators may
b
e connecte
d
i
n para
ll
e
l
.
P
ower consumpt
i
on an
d
i
nput
i
mpe
d
ance must
b
e o
b
serve
d
.
3
N
o ground connection is required
.
4
F
or end position indication, interlock control,
f
an startup, etc.,
AFBUP-S N4(H), AFXUP-S N4 incorporates two built-in auxiliary switches:
2 x SPDT, 3A
(
0.5A
)
@250 VAC, UL Approved, one switch is fi xed at +10°,
one is ad
j
ustable 10° to 90°
.
Meets cULus requirements without the need of an electrical ground con
-
nect
i
on.
WARNING
Live Electrical Components!
G
During installation, testing, servicing and troubleshooting o
f
this product, it may be
necessary to work with live electrical components. Have a quali
ed licensed electrician or other
individual who has been properly trained in handlin
g
live electrical components per
f
orm these
tasks. Failure to
f
ollow all electrical sa
f
ety precautions when exposed to live electrical compo-
nents could result in death or serious injury
.
N40103 - 09/11 - Subject to change. © Belimo Aircontrols (USA), Inc.

Other manuals for Belimo AFX24-MFT

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Belimo AFX24-MFT and is the answer not in the manual?

Belimo AFX24-MFT Specifications

General IconGeneral
BrandBelimo
ModelAFX24-MFT
CategoryController
LanguageEnglish

Related product manuals