1. GENERAL
1.01 This section provides maintenance and
connection information for the 2565LK
telephone sets. Maintenance information was
formerly found in Section 502-525-125. Connection
information was formerly found in Section 502-525-437
which is hereby canceled.
2. MAINTENANCE
Replaceable Components
2.01 Field replaceable items are listed under
Ordering Guide in the appropriate Reference
section in Division 502.
Loose Card Retainers
2.02 Current production sets are equipped with
P-25E803 and P-269561 card retainers, which
cannot be adjusted.
2.03 If P-25E785 (MD) card retainer becomes so
loose on the faceplate that the number card
or designation strip slips, they can be tightened
as follows:
(1) Remove faceplate from set.
(2) Remove card retainer from faceplate.
(3) Bend the four arms of the retainer so that
more pressure will be applied to the number
card and designation strip. The bends should
be made approximately 1/2-inch in from the tabs
on the ends of the arms and in the opposite
direction from the factory bent tabs.
(4) Install the card retainer on the faceplate
and insert the number card and designation
strip.
(5) Install faceplate on telephone set.
Note: If adjusting the arms of the retainer
does not result in sufficient holding power,
replace the card retainer.
Housing
2.04 When removing or replacing housing, guide
lower front of housing over pushbuttons.
On sets equipped with exclusion, pull exclusion
plunger up to its operated position before removing
housing. Plunger should also be in upper position
when replacing housing. With housing in place,
operate plunger several times to insure proper
operation.
Lamps and Pushbuttons
2.05 Replace cracked pushbuttons or collar
assemblies. Plastic parts may be cleaned
with a water dampened cloth. DO NOT USE
SOLVENTS. Lamps should be near associated
pushbutton with contact surfaces aligned for
maximum illumination.
2.06 To replace defective lamp.
(1) Remove button and collar assembly.
(2) Gently pry lamp from socket with KS-6320
orange stick.
(3) Replace lamp, making sure that contact
surface on lamp and socket meet.
(4) Replace button and collar assembly.
Keys—589-Type
2.07 Key contacts may be cleaned using a 265C
tool, or adjusted using a 363 tool. When
adjusting springs:
(a) There should be a minimum clearance of
1/64-inch between contact springs and those
parts of the key which do not make contact.
(c) American Telephone and Telegraph Company. 1970
Printed in U.S.A. Page 1

Table of Contents

Other manuals for Bell System Practices Plant Series

Question and Answer IconNeed help?

Do you have a question about the Bell System Practices Plant Series and is the answer not in the manual?

Bell System Practices Plant Series Specifications

General IconGeneral
BrandBell System Practices
ModelPlant Series
CategoryTelephone
LanguageEnglish