Overview

The provided document is an installation and maintenance manual for the Bellfires Smart Bell 65/60 MF gas fire. This decorative gas fire is designed to heat a room and can be installed as an insertion into an existing open fireplace or as a built-in appliance in a new fireplace. It is intended for use in a completely sealed or mechanically ventilated house without extra ventilation and/or fume extraction.

Function Description

The Smart Bell 65/60 MF is a room-sealed, independent gas-fired convection heater. It operates with a MagniFire double burner system, which provides both an upper and lower fire for a realistic flame effect. Combustion air is supplied to the appliance, and flue gases are extracted through a concentric flue system. The appliance features heat-resistant glass that keeps flue gases inside and closes off the combustion chamber.

Key components and their functions include:

  • Control unit: Contains the gas regulator block, receiver, and the fan/light module, managing the appliance's operation.
  • Inlet grate: Provides air to the fireplace.
  • Outlet grate: Extracts heated air from the fireplace into the room.
  • Concentric flue system: Supplies combustion air and extracts flue gases. It can be configured with a wall outlet or a roof-mounted outlet.
  • Convection fan set (optional): Collects heated convection air and releases it into the room, enhancing heat distribution.
  • Overpressure door: A safety device that opens for a short duration if an overpressure occurs, protecting the appliance.
  • Burner bed: The top surface of the gas burner and grate, where the ceramic log set is placed.
  • Pilot light burner: Provides a pilot light for ignition.
  • Thermocouple: Detects if the pilot light is on, ensuring safe gas supply.
  • Ignition electrode: Supplies a spark to ignite the pilot light.
  • Gas regulator block: Manages gas flow and pressure to the burners and pilot light. It includes adjustment screws for pilot gas pressure and maximum burner pressure, which are factory set and sealed.
  • Receiver: Processes signals from the remote control and communicates with the gas regulator block and fan/light module. It can be optionally connected to a 6 VDC adapter, a wall switch/domotica system, or a wifi-box for smartphone control via the Bellfires app.
  • Fan/light module: Powers the convection fan (optional) and ambient light bulbs, and controls their functions.

Important Technical Specifications

The Smart Bell 65/60 MF is available in both Natural gas (G20) and Butane/Propane (G30/G31) versions.

General:

  • Product identification no: 0063CM3684
  • Type of appliance under CE-norm: C11/C31/C91
  • Category of appliance: I2H natural gas G20 or I3B/P butane/propane G30/G31
  • Energy efficiency class: B
  • Energy efficiency index (EEI): 82
  • Electrical connection: 230 VAC / 50 Hz
  • Batteries remote control hand transmitter: 2x 1.5V AAA
  • Weight (Basic model): 61 kg
  • Weight (Including Storage module): 64 kg

Natural Gas (G20):

  • Nominal heat input (Gross calorific value): 7.0 kW
  • Nominal heat output: 5.3 kW
  • Minimum heat output (indicative): 2.6 kW
  • Useful efficiency (Net Calorific Value (NCV)) at nominal heat output: 84.3%
  • Useful efficiency (Net Calorific Value (NCV)) at minimum heat output (indicative): 77.1%
  • NOx (max.) (Gross Calorific Value (GCV)): <130 mg/kWhinput
  • NOx class: 4
  • Gas rate (max.): 0.66 m³/hr.
  • Supply pressure: 20.0 mbar
  • Burner pressure (max.) Hot: 12.0 mbar (*)
  • Burner pressure (max.) Cold: 11.3 mbar (**)
  • Burner pressure (min.): 4.0 mbar (***)
  • Gas connection: 3/8" G / Ø12 mm
  • Concentric flue system connection: Ø100 mm - Ø150 mm
  • Main burner injector Rear/Front: no 160 (= 1x Ø1.60 mm)
  • Pilot light burner injector: no 36 (SIT 0.977.091)

Butane/Propane (G30/G31):

  • Nominal heat input (Gross calorific value): Butane (G30): 7.3 kW, Propane (G31): 6.0 kW
  • Nominal heat output: Butane (G30): 5.6 kW, Propane (G31): 4.6 kW
  • Minimum heat output (indicative): Butane (G30): 2.6 kW, Propane (G31): 2.1 kW
  • Useful efficiency (Net Calorific Value (NCV)) at nominal heat output: 85.5%
  • Useful efficiency (Net Calorific Value (NCV)) at minimum heat output (indicative): 78.8%
  • NOx (max.) (Gross Calorific Value (GCV)): <130 mg/kWhinput
  • NOx class: 4
  • Gas rate (max.): Butane (G30): 550 gr/hr., Propane (G31): 440 gr/hr.
  • Supply pressure: Butane (G30): 37.0 mbar, Propane (G31): 37.0 mbar
  • Burner pressure (max.) Hot: 29.0 mbar (*)
  • Burner pressure (max.) Cold: 29.0 mbar (**)
  • Burner pressure (min.): 7.0 mbar (***)
  • Gas connection: 3/8" G / Ø12 mm
  • Concentric flue system connection: Ø100 mm - Ø150 mm
  • Main burner injector Rear: no 90 (= 1x Ø0.90 mm)
  • Main burner injector Front: no 100 (= 1x Ø1.00 mm)
  • Pilot light burner injector: no 23 (SIT 0.977.150)

() Both burners at maximum. Appliance is on temperature. () Both burners at maximum. Appliance is cold. () Both burners at minimum.

Usage Features

  • Remote control operation: The appliance is controlled via a remote control, allowing for ignition, flame height adjustment, and control of ambient lighting and convection fan speed (if installed).
  • Ceramic log set: The appliance uses a ceramic log set, including ember grates, 'Fire glass' Dark Amber, embers, logs, and charcoal pieces, to create a realistic fire effect. Correct placement of these items is crucial for safe and optimal operation.
  • Ambient lighting: The appliance includes ambient light bulbs to enhance the visual appeal of the fire.
  • Convection fan (optional): Improves heat distribution in the room.
  • Mantel iron (optional): Allows for building brickwork beyond the height of the appliance.
  • Built-in or insertion installation: Versatile installation options to suit different fireplace designs.

Maintenance Features

The manual outlines annual maintenance procedures to ensure the appliance's longevity and safe operation.

Annual Maintenance:

  • Cleaning:
    • Remove the door (including glass) and the ceramic log set from the burner bed.
    • Clean the removed content carefully with a soft brush.
    • Clean the inside of the appliance, including the main burner, pilot light burner, and flue system.
    • Clean the combustion air intake and primary combustion air inlet openings.
    • Clean ambient light bulbs and the convection air route.
    • If installed, clean the convection fan carefully with a soft brush.
    • Clean the glass with glass spray or ceramic hob cleaner.
    • If a black mirror rear wall is installed, clean it with glass spray or ceramic hob cleaner.
  • Checks:
    • Check for leaks on gas pipes and connections using soapy water or a leak tester.
    • Verify correct operation of the pilot light and main burner (quiet ignition, calm flame, flames increasing in height and changing from blue/yellow to yellow).
    • Check gas supply pressure and burner pressure using inlet and outlet pressure taps on the gas regulator block.
    • Ensure ambient lighting operates correctly.
    • If a convection fan is installed, ensure it works correctly.
    • Check the concentric flue system and outlet construction for secure connections.
    • Inspect the inside of the appliance for damage, including the main burner, pilot burner, combustion air intake, and flue system.
  • Component replacement:
    • Instructions are provided for replacing the ambient light bulb if broken, emphasizing the use of original Bellfires bulbs.
  • Door and frame removal/installation: Detailed steps are provided for safely removing and installing the door (including glass) and the frame for maintenance access.
  • Flue gas restriction plate: Instructions for installing and removing the flue gas restriction plate, which is crucial for correct appliance operation. The baffle plate must be removed if a restriction plate is not needed.

Safety during maintenance:

  • Always turn off the gas supply and power supply to the appliance before cleaning or performing any maintenance.
  • Use only original parts for replacement.
  • Do not introduce unauthorized modifications to the appliance.
  • Ensure the door and glass pane fit properly to prevent flue gas leakage.

The manual also includes a troubleshooting section to address common issues such as the main fire stopping, the appliance not reacting to the remote control, pilot burner issues, and light/fan malfunctions.