1
BB-2000
Housing
Tools
Phillips screw driver
Flat head screw driver
Contact
847.458.2334
support@biobidet.com
This is a guide for replacing the housing for the BB-2000. Follow along to the instructions
depending on which part you have that needs replacing instructions. Bio Bidet By Bemis is not
responsible for any damages that result from aempng this repair/replacement at home. If
you do not feel comfortable attempting this repair/replacement, please contact us to obtain an RMA
and return the bidet to our service center. *Be aware that replacing the seat involves wiring*
Before You Begin
• Unplug the bidet
• Turn off the water valve and drain the bidet
• Disconnect the bidet from the water supply and toilet and place on
a at, dry, and well-lit surface
Remove Lid Open Housing
• Pull out the right ear on the lid to remove the
lid from the housingThe lid must be removed
in order to change the dampers and seat.
• Remove the two screws located
on the back of the bidet.
• Pop out the housing. Loosening several parts
around the housing will make it easier for it to come apart.
PCB
• There are 3 wires from the seat that are connected to the PCB. Remove the clips from the green, black,
and yellow receptacles. Do not aempt to remove any other wires.