Backlight | No |
---|---|
Product type | Digital multimeter |
Product color | Red |
AC current range | 0.1 - 300 A |
AC voltage range | 0.001 - 600 V |
Continuity check | Yes |
DC current range | 0.01 - 300 A |
DC voltage range | 0.0001 - 600 V |
Resistance range | 0.1 - 40 Ω |
Measuring category | CAT III 300V |
Placement supported | Handheld multimeter |
Test lead length | 1.4 m |
Battery type | AAA |
Power source | Battery |
Battery voltage | 1.5 V |
Battery technology | Alkaline |
Number of batteries supported | 2 |
Operating altitude | 0 - 2000 m |
Storage temperature (T-T) | -20 - 60 °C |
Operating temperature (T-T) | 0 - 50 °C |
Operating relative humidity (H-H) | 50 - 80 % |
Depth | 66 mm |
---|---|
Width | 192 mm |
Height | 27 mm |
Weight | 205 g |
Overview of the multimeter's front panel, including housing, sliding switch, display, and function buttons.
Details on display, polarity, overload, measuring rate, auto-off, temperature coefficients, battery, and dimensions.
Specifies barometric height, overvoltage category, protection class, and operating temperature/humidity limits.
Specifies measuring ranges, resolution, accuracy, and overload protection for DC voltage measurements.
Details measuring ranges, resolution, accuracy, and overload protection for AC voltage measurements.
Lists measuring ranges, resolution, accuracy, and overload protection for resistance measurements.
Describes the continuity test function, including buzzer operation and resistance threshold.
Provides details on measuring ranges, resolution, accuracy, and overload protection for DC current.
Specifies measuring ranges, resolution, accuracy, and overload protection for AC current.
Explains the MAX-Hold display accuracy and limitations for resistance measurements.
Guidance on proper storage, usage conditions, and checking safety measuring wires before measurements.
Step-by-step instructions for performing voltage measurements, including safety warnings.
Instructions for measuring resistance, emphasizing zero voltage and potential accuracy improvements.
How to perform a continuity test using the buzzer function and connect the device.
Steps for measuring current, including preparation, zeroing, and using the prongs.
Procedure to ensure the unit is de-energized and safe before performing maintenance.
Guidelines for cleaning the exterior of the multimeter and battery contacts safely.
Instructions for replacing the batteries, including safety precautions and battery disposal advice.
Information on the importance of regular calibration and the factory service address.
Technical details for the safety test leads, including voltage/current ratings, insulation, and environmental conditions.