EasyManua.ls Logo

Bently Nevada 3300/20 User Manual

Bently Nevada 3300/20
93 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Artisan Technology Group is your source for quality
new and certied-used/pre-owned equipment
FAST SHIPPING AND
DELIVERY
TENS OF THOUSANDS OF
IN-STOCK ITEMS
EQUIPMENT DEMOS
HUNDREDS OF
MANUFACTURERS
SUPPORTED
LEASING/MONTHLY
RENTALS
ITAR CERTIFIED
SECURE ASSET SOLUTIONS
SERVICE CENTER REPAIRS
Experienced engineers and technicians on staff
at our full-service, in-house repair center
WE BUY USED EQUIPMENT
Sell your excess, underutilized, and idle used equipment
We also offer credit for buy-backs and trade-ins
www.artisantg.com/WeBuyEquipment
REMOTE INSPECTION
Remotely inspect equipment before purchasing with
our interactive website at www.instraview.com
LOOKING FOR MORE INFORMATION?
Visit us on the web at www.artisantg.com for more
information on price quotations, drivers, technical
specications, manuals, and documentation
Contact us: (888) 88-SOURCE | sales@artisantg.com | www.artisantg.com
SM
View
Instra
Question and Answer IconNeed help?

Do you have a question about the Bently Nevada 3300/20 and is the answer not in the manual?

Bently Nevada 3300/20 Specifications

General IconGeneral
BrandBently Nevada
Model3300/20
CategoryMeasuring Instruments
LanguageEnglish

Summary

NOTICE

WARNING

High voltage present could cause shock, burns or death. Do not touch exposed wires or terminals.

CAUTION

Machine Protection Could Be Discontinued.

SYMBOLS

Special symbols are used in the manual to illustrate step-by-step process.

FOREWORD

DUAL THRUST MONITOR SYSTEM

MONITOR FUNCTIONS

DUAL THRUST POSITION

Thrust position is the average position or change in position of a rotor relative to a fixed reference.

PROBE GAP VOLTAGE

Probe gap is measured as a negative de voltage proportional to the gap distance between probe and surface.

ALARM

Pressing ALERT/DANGER switches displays setpoints; LEDs light when signal exceeds levels.

SELF TEST

Monitor has three self-test categories: cyclic, power-up, and user-invoked.

MONITOR OPTIONS

PROGRAMMABLE OPTIONS

OK

BYPASS

ALERT

DANGER

MONITOR RANGES

READ CHANNEL THRUST POSITION

READ GAP VOLTAGE

READ ALERT SETPOINT LEVELS

READ DANGER SETPOINT LEVELS

SELF TEST