EasyManuals Logo

Beretta CIAO AT 29 C.S.I. User Manual

Beretta CIAO AT 29 C.S.I.
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #14 background imageLoading...
Page #14 background image
ENGLISH
14
CIAO AT 25 C.S.I.
CIAO AT 29 C.S.I.
Seasonal space heating energy efficiency
class
B
Water heating energy efficiency
class
A
Parameter Symbol Value Unit Parameter Symbol Value Unit
Rated heat output Prated 24 kW
Seasonal space heating energy
efficiency
ηs 86 %
For boiler space heaters and boiler combination heaters:
useful heat output
For boiler space heaters and boiler combination heaters:
useful efficiency
At rated heat output and high-
temperature regime (*)
P4 24,4 kW
At rated heat output and high-
temperature regime (*)
η4 87,7 %
At 30% of rated heat output and
low-temperature regime (**)
P1 7,5 kW
At 30% of rated heat output and
low-temperature regime (**)
η1 90,1 %
Auxiliary electricity consumption Other parameters
At full load elmax 90,0 W Stand-by heat loss Pstby 40,0 W
At part load elmin 28,4 W Pilot flame energy consumption Pign - W
In Stand-by mode PSB 2,0 W Annual energy consumption QHE 82 GJ
Sound power level, indoors LWA 50 dB
Emissions of nitrogen oxides NOx 149
mg/
kWh
For combination heaters:
Declared load profile XL Water heating energy efficiency ηwh 81 %
Daily electricity consumption Qelec 0,220 kWh Daily fuel consumption Qfuel 24,122 kWh
Annual electricity consumption AEC 48 kWh Annual fuel consumption AFC 18 GJ
(*) High-temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet.
(**) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return temperature (at heater
inlet).
Seasonal space heating energy efficiency
class
B
Water heating energy efficiency
class
A
Parameter Symbol Value Unit Parameter Symbol Value Unit
Rated heat output Prated 28 kW
Seasonal space heating energy
efficiency
ηs 86 %
For boiler space heaters and boiler combination heaters:
useful heat output
For boiler space heaters and boiler combination heaters:
useful efficiency
At rated heat output and high-
temperature regime (*)
P4 28,3 kW
At rated heat output and high-
temperature regime (*)
η4 87,9 %
At 30% of rated heat output and
low-temperature regime (**)
P1 8,7 kW
At 30% of rated heat output and
low-temperature regime (**)
η1 89,6 %
Auxiliary electricity consumption Other parameters
At full load elmax 75,0 W Stand-by heat loss Pstby 40,0 W
At part load elmin 23,9 W Pilot flame energy consumption Pign - W
In Stand-by mode PSB 2,0 W Annual energy consumption QHE 95 GJ
Sound power level, indoors LWA 50 dB
Emissions of nitrogen oxides NOx 146
mg/
kWh
For combination heaters:
Declared load profile XL Water heating energy efficiency ηwh 82 %
Daily electricity consumption Qelec 0,207 kWh Daily fuel consumption Qfuel 23,811 kWh
Annual electricity consumption AEC 45 kWh Annual fuel consumption AFC 18 GJ
(*) High-temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet.
(**
) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return temperature (at heater inlet).

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Beretta CIAO AT 29 C.S.I. and is the answer not in the manual?

Beretta CIAO AT 29 C.S.I. Specifications

General IconGeneral
BrandBeretta
ModelCIAO AT 29 C.S.I.
CategoryBoiler
LanguageEnglish

Related product manuals